EUVIMEDEUVIMED entdecken
Crossref

Resolving Spectral Complexity in 4D Lipidomics Using a Two‐Dimensional Deconvolution Framework

Yao Qian, Qirui Yu, Zhixu Ni iD, Zheng Ouyang, Xiaoxiao Ma iD

Angewandte Chemie International Edition · 2026

DOI: 10.1002/anie.6117030 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Angewandte Chemie International Edition, 2026. Verfasst von Yao Qian und 4 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, China. Hauptthemen laut MEDLINE: Lipidomics, Lipids. Die Arbeit nennt 50 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National High Level Hospital Clinical Research, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The application of data‐independent acquisition (DIA) in 4D lipidomics has been constrained by spectral interference due to fragment ion overlap, a bottleneck that existing one‐dimensional deconvolution methods fail to fully resolve. Here, we overcome this limitation by introducing a two‐dimensional liquid chromatography‐ion mobility (LC‐IM) deconvolution framework that unlocks the full potential of 4D lipidomics. By mathematically modeling the orthogonal LC‐IM separation dimensions, our method reconstructs high‐quality MS/MS spectra from highly complex DIA data, effectively disentangling co‐eluting lipid interferences. We demonstrate the power of this approach by annotating 491 lipids from 1 µL human plasma at a 1% false discovery rate, a two‐fold increase in coverage compared to traditional methods. Beyond bulk analysis, we showcase its unique capability for spatial lipidomics, enabling deep profiling of laser‐microdissected tissue regions equivalent to only hundreds of cells, revealing metabolic reprogramming in human hepatocellular carcinoma. We further integrate this workflow with six‐plex isobaric labeling to achieve high‐throughput, high‐accuracy quantification in spatial tissue mapping. This transition from one‐ to two‐dimensional deconvolution establishes a robust, sensitive platform for deep lipidome characterization, bridging the gap between proteomics‐grade throughput and lipidomic structural complexity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LipidomicsLipidsHumansTandem Mass SpectrometryChromatography, LiquidLiquid Chromatography-Mass Spectrometry

Stichwörter der Autor:innen

data‐independent acquisitiondeconvolutionion mobilitylipidomicsmass spectrometry

Substanzen

Lipids

Autor:innen und Institutionen

  • State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, China.
  • Shenzhen International Graduate School, Tsinghua University, Shenzhen, China.

ORCID-Profile: Zhixu Ni, Xiaoxiao Ma

Förderung

  • National Key Research and Development Program of China
  • National High Level Hospital Clinical Research
  • National Natural Science Foundation of China

Zitieren

APA

Qian, Y., Yu, Q., Ni, Z., Ouyang, Z., & Ma, X. (2026). Resolving Spectral Complexity in 4D Lipidomics Using a Two‐Dimensional Deconvolution Framework. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.6117030

Vancouver

Qian Y, Yu Q, Ni Z, Ouyang Z, Ma X. Resolving Spectral Complexity in 4D Lipidomics Using a Two‐Dimensional Deconvolution Framework. Angewandte Chemie International Edition. 2026. doi:10.1002/anie.6117030

BibTeX
@article{Qian2026,
  author = {Qian, Yao and Yu, Qirui and Ni, Zhixu and Ouyang, Zheng and Ma, Xiaoxiao},
  title = {Resolving Spectral Complexity in 4D Lipidomics Using a Two‐Dimensional Deconvolution Framework},
  journal = {Angewandte Chemie International Edition},
  year = {2026},
  doi = {10.1002/anie.6117030}
}