Striping artifact removal in VisiumHD data through nuclear counts modeling
Bioinformatics · 2026
DOI: 10.1093/bioinformatics/btag306 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioinformatics, 2026. Verfasst von Paola Malsot und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Computer Science, ETH Zurich, Zürich, 8092, Switzerland. Hauptthemen laut MEDLINE: Artifacts, Cell Nucleus, Image Processing, Computer-Assisted, Genomics. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Motivation 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. Results We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. Availability and Implementation All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Computer Science, ETH Zurich, Zürich, 8092, Switzerland.
- ETH AI Center, ETH Zurich, Zürich, 8092, Switzerland.
- Seminar for Statistics, ETH Zurich, Zürich, 8092, Switzerland.
- Swiss Institute for Bioinformatics, Zürich, 8092, Switzerland.
- Medical Informatics Unit, University Hospital Zurich, Zürich, 8091, Switzerland.
ORCID-Profile: Paola Malsot, Malte Londschien, Valentina Boeva
Zitieren
APA
Malsot, P., Londschien, M., Boeva, V., & Rätsch, G. (2026). Striping artifact removal in VisiumHD data through nuclear counts modeling. Bioinformatics. https://doi.org/10.1093/bioinformatics/btag306
Vancouver
Malsot P, Londschien M, Boeva V, Rätsch G. Striping artifact removal in VisiumHD data through nuclear counts modeling. Bioinformatics. 2026. doi:10.1093/bioinformatics/btag306
BibTeX
@article{Malsot2026,
author = {Malsot, Paola and Londschien, Malte and Boeva, Valentina and Rätsch, Gunnar},
title = {Striping artifact removal in VisiumHD data through nuclear counts modeling},
journal = {Bioinformatics},
year = {2026},
doi = {10.1093/bioinformatics/btag306}
}
EUVIMED