Recommended flow rate of the aluminum cyclone for improved exposure assessment
Annals of Work Exposures and Health · 2025
DOI: 10.1093/annweh/wxaf075 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Work Exposures and Health, 2025. Verfasst von Sena Yang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Health Hazards Prevention Branch, Centers for Disease Control and Prevention, Pittsburgh Mining Research Division, National Institute for Occupationa…. Hauptthemen laut MEDLINE: Aluminum, Occupational Exposure, Inhalation Exposure, Air Pollutants, Occupational. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: NIOSH CDC HHS, NIOSH.
Abstract (Originalsprache)
Samples of the respirable fraction of airborne particles to which workers are exposed are an important component of many health protection programs, especially in those workplaces where there is a risk of health problems from exposure to respirable crystalline silica. The most common technique for size-selection of the respirable dust fraction is to use a miniature cyclone preselector, many of which are based on the “Higgens-Dewell” (HD) design. A variant of the HD cyclone, commonly referred to as the “aluminum (or aluminium) cyclone,” was developed in Scandinavia. Early work showed that a flow rate of 2.2 l min−1 would be appropriate to meet the size-separation convention standardized under the International Organization for Standardization (ISO), while a later, non-peer-reviewed study suggested 2.5 l min−1 and this flow rate is currently recommended by the manufacturers. The International Sampler Comparison Group is working on revising the European Standard EN13205 on sampler performance testing for consideration as an ISO standard. In this work, 5 aluminum cyclone units were tested at 2.5 l min−1 and the cyclones were further tested at 2.3 and 2.2 l min−1 to determine the optimal flow rate. While the flow rate of 2.3 l min−1 had the lowest overall mean bias, a flow rate of 2.2 l min−1 gave bias <±10% over the whole area of size distributions of interest. This supports earlier findings and suggests that 2.2 l min−1 is the most accurate flow rate for sampling with the aluminum cyclone. However, 2.3 l min−1 also meets the specification of EN13205 in that the area of bias >±10% is minimal. The consequence of continuing to use the aluminum cyclone at 2.5 l min−1 is an underestimate of respirable particles when compared with the ISO convention.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Health Hazards Prevention Branch, Centers for Disease Control and Prevention, Pittsburgh Mining Research Division, National Institute for Occupational Safety and Health, 626 Cochrans Mill Road, Pittsburgh, PA 15236, Uni…
- Department of Environmental Engineering Sciences, University of Florida, Black Hall, 1128 Center Drive, Gainesville, FL 32611, United States.
ORCID-Profile: Taekhee Lee
Förderung
- NIOSH CDC HHS
- NIOSH
Zitieren
APA
Yang, S., Harper, M., Cauda, E., & Lee, T. (2025). Recommended flow rate of the aluminum cyclone for improved exposure assessment. Annals of Work Exposures and Health. https://doi.org/10.1093/annweh/wxaf075
Vancouver
Yang S, Harper M, Cauda E, Lee T. Recommended flow rate of the aluminum cyclone for improved exposure assessment. Annals of Work Exposures and Health. 2025. doi:10.1093/annweh/wxaf075
BibTeX
@article{Yang2025,
author = {Yang, Sena and Harper, Martin and Cauda, Emanuele and Lee, Taekhee},
title = {Recommended flow rate of the aluminum cyclone for improved exposure assessment},
journal = {Annals of Work Exposures and Health},
year = {2025},
doi = {10.1093/annweh/wxaf075}
}
EUVIMED