EUVIMEDEUVIMED entdecken
Crossref

Accuracy of Patient-Collected Vital Signs

Joshua P Metlay, Ralph Gonzales, Timothy J Judson, Yuchiao Chang, Justin Margolin, Samir Oza, Blair A Parry iD, Michelle D Tagerman, Emily Hayden

Telemedicine and e-Health · 2024-11 · 30 (11) · 2747-2751

DOI: 10.1089/tmj.2023.0548 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Telemedicine and e-Health, online erschienen am 16.08.2024. Verfasst von Joshua P Metlay und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Massachusetts General Hospital, Boston, Massachusetts, USA. Hauptthemen laut MEDLINE: Vital Signs, Telemedicine. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 11 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Telehealth has emerged as an important clinical setting for managing acute respiratory tract infections (ARIs), potentially reducing emergency department and urgent care overcrowding, and reducing nosocomial transmission. Many current algorithms for ARI management incorporate information on patient vital signs. However, the accuracy of vital signs collected by patients using readily available home devices and techniques has not been studied.

Methods

A cross-sectional sample of patients seen for urgent conditions at a hospital emergency and urgent care center were given instructions and low-cost, readily available devices to collect their vital signs. A trained research coordinator collected a parallel set of vital signs using standard hospital equipment, serving as the gold standard. We analyzed the performance of patient-collected vital signs compared with vital signs collected by a trained research coordinator.

Results

A total of 300 patients completed the study. Patient-collected vital signs were highly specific for traditional levels of abnormalities (HR >100 beats per min, RR >24 breaths per min, temperature >100.4 degrees Fahrenheit, oxygen saturation

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Vital SignsTelemedicineHumansCross-Sectional StudiesFemaleMaleAdultMiddle AgedAgedRespiratory Tract InfectionsYoung AdultSensitivity and SpecificityAdolescent

Stichwörter der Autor:innen

cross-sectional studiesemergency servicestelemedicinevital signs

Autor:innen und Institutionen

  • Department of Medicine, Massachusetts General Hospital, Boston, Massachusetts, USA.
  • Department of Medicine, University of California, San Francisco, California, USA.
  • Department of Emergency Medicine, Massachusetts General Hospital, Boston, Massachusetts, USA.

ORCID-Profile: Blair A Parry

Zitieren

APA

Metlay, J. P., Gonzales, R., Judson, T. J., Chang, Y., Margolin, J., Oza, S., Parry, B. A., Tagerman, M. D., & Hayden, E. (2024). Accuracy of Patient-Collected Vital Signs. Telemedicine and e-Health, 30(11), 2747-2751. https://doi.org/10.1089/tmj.2023.0548

Vancouver

Metlay JP, Gonzales R, Judson TJ, Chang Y, Margolin J, Oza S, et al. Accuracy of Patient-Collected Vital Signs. Telemedicine and e-Health. 2024;30(11):2747-2751. doi:10.1089/tmj.2023.0548

BibTeX
@article{Metlay2024,
  author = {Metlay, Joshua P and Gonzales, Ralph and Judson, Timothy J and Chang, Yuchiao and Margolin, Justin and Oza, Samir and Parry, Blair A and Tagerman, Michelle D and Hayden, Emily},
  title = {Accuracy of Patient-Collected Vital Signs},
  journal = {Telemedicine and e-Health},
  year = {2024},
  volume = {30},
  number = {11},
  pages = {2747--2751},
  doi = {10.1089/tmj.2023.0548}
}
Kostenlos starten →