Effects of Trigger Algorithms on Trigger Performance and Patient–Ventilator Synchrony
Respiratory Care · 2025
DOI: 10.1089/respcare.12694 ↗Kurz gefasst
Fachartikel in der Zeitschrift Respiratory Care, 2025. Verfasst von Keisuke Morinishi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Mr. Morinishi and Mr. Chikata are affiliated with Division of Clinical Engineering, Tokushima University Hospital, Tokushima, Japan. Hauptthemen laut MEDLINE: Algorithms, Respiratory Distress Syndrome, Respiratory Mechanics, Respiration, Artificial. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 21 Literaturangaben.
Abstract (Originalsprache)
Background
Patient–ventilator synchrony is essential for successful patient-triggered ventilation. This study compared the ability of a trigger algorithm, based on detailed analysis of flow changes (IntelliSync+, Hamilton Medical), to trigger patient breaths with conventional algorithms.
Methods
Three models with different lung mechanics (normal, ARDS, and COPD) at 3 severities were simulated with a lung model ventilated in pressure control continuous mandatory ventilation or pressure control continuous spontaneous ventilation (PC-CSV). Inspiratory pressure above PEEP was set at 15 cm H 2 O and PEEP at 5 cm H 2 O. Inspiratory trigger was selected from IntelliSync+ (IS+insp), flow trigger (1– 5 L/min), or pressure trigger (−1 to −5 cm H 2 O). In PC-CSV, expiratory trigger was set at IntelliSync+ (IS+exp) or cycling criteria (5%, 25%, and 40% for ARDS, normal, and COPD, respectively). Measurements were performed with and without leak (50% inspiratory tidal volume). Five breaths per condition were collected to calculate trigger delay time and asynchronous events.
Results
For pressure trigger, none of the conditions resulted in 3 successfully triggered consecutive breaths. Overall trigger delay time was significantly longer with flow trigger than with IS+insp in normal (99 vs 81 ms without leak, P < .001; 98 vs 80 ms with leak, P < .001) and ARDS models (334 vs 223 ms without leak, P < .001; 320 vs 236 ms with leak, P = .02). Across all conditions, ineffective efforts occurred more frequently with flow trigger than with IS+insp (7.3% vs 1.5% without leak, P = .01; 10.8% vs 3.0% with leak, P = .01). In PC-CSV, overall cycling delay time with IS+exp was equivalent or longer compared with cycling criteria.
Conclusions
In this lung model study, IS+insp demonstrated similar trigger time and fewer ineffective efforts compared with flow trigger even in simulated respiratory conditions, whereas cycling delay time was unaffected by IS+exp because of large variations between conditions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Mr. Morinishi and Mr. Chikata are affiliated with Division of Clinical Engineering, Tokushima University Hospital, Tokushima, Japan.
- Dr. Itagaki is affiliated with Emergency and Disaster Medicine, Tokushima University Hospital, Tokushima, Japan.
- Dr. Akimoto is affiliated with Emergency Department, Tokushima Prefectural Miyoshi Hospital, Miyoshi, Japan.
- Drs. Akimoto and Oto are affiliated with Emergency and Critical Care Medicine, Tokushima University Graduate School of Biomedical Sciences, Tokushima, Japan.
ORCID-Profile: Taiga Itagaki
Zitieren
APA
Morinishi, K., Itagaki, T., Akimoto, Y., Chikata, Y., & Oto, J. (2025). Effects of Trigger Algorithms on Trigger Performance and Patient–Ventilator Synchrony. Respiratory Care. https://doi.org/10.1089/respcare.12694
Vancouver
Morinishi K, Itagaki T, Akimoto Y, Chikata Y, Oto J. Effects of Trigger Algorithms on Trigger Performance and Patient–Ventilator Synchrony. Respiratory Care. 2025. doi:10.1089/respcare.12694
BibTeX
@article{Morinishi2025,
author = {Morinishi, Keisuke and Itagaki, Taiga and Akimoto, Yusuke and Chikata, Yusuke and Oto, Jun},
title = {Effects of Trigger Algorithms on Trigger Performance and Patient–Ventilator Synchrony},
journal = {Respiratory Care},
year = {2025},
doi = {10.1089/respcare.12694}
}
EUVIMED