EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access · CC BY 4.0

A novel positive end-expiratory pressure titration using electrical impedance tomography in spontaneously breathing acute respiratory distress syndrome patients on mechanical ventilation: an observational study from the MaastrICCht cohort

Neue positive-endexpiratory-pressure-Titration mit elektrischer Impedanztomographie bei spontan atmenden ARDS-Patient:innen unter mechanischer Beatmung: Beobachtungsstudie aus der MaastrICCht-Kohorte

S J H Heines iD, S A M de Jongh iD, F H C de Jongh iD, R P J Segers, K M H Gilissen, I C C van der Horst iD, B C T van Bussel iD, D C J J Bergmans iD

Journal of Clinical Monitoring and Computing · 28.08.2024 · 39 (1) · 127-139

DOI: 10.1007/s10877-024-01212-8 ↗

Auf einen Blick

Bei 25 COVID-19-ARDS-Patient:innen unter spontaner mechanischer Beatmung war eine EIT-gestützte PEEP-Titration mit RPF durchführbar. Ein Schwellenwert von etwa 5 % kumulativer Kollaps schien den besten Kompromiss zu bieten.

Fragestellung

Ist die RPF-Methode mittels elektrischer Impedanztomographie für die PEEP-Titration während spontaner mechanischer Beatmung machbar?

Methode

Beobachtungsstudie mit Einzel-EIT-Messungen bei COVID-19-ARDS-Patient:innen unter spontaner mechanischer Beatmung; Vergleich vordefinierter PEEP-Schwellen mit dem Ausgangs-PEEP.

Ergebnisse

25 Patient:innen. Keine signifikanten und klinisch relevanten Unterschiede für Tidalvolumen, endtidales CO2 und P0.1 gegenüber dem Ausgangs-PEEP. Die mechanischen Parameter und PEEP-Niveaus variierten je nach Schwelle.

Einschränkungen

Langfristige klinische Sicherheit und Wirkung dieser Methode wurden nicht bestimmt.

Schlussfolgerung der Autor:innen

Die EIT-gestützte PEEP-Titration über den RPF-Ansatz ist während spontaner mechanischer Beatmung machbar und mit einer verbesserten Gesamt-Lungenmechanik verbunden; die Wirkung und Sicherheit langfristig bleiben offen.

Kernaussagen

  • RPF per EIT war bei spontaner Beatmung anwendbar
  • Etwa 5 % kumulativer Kollaps schien günstig
  • Langzeit-Sicherheit und klinischer Effekt sind unklar

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Journal of Clinical Monitoring and Computing, online erschienen am 28.08.2024. Verfasst von S J H Heines und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Intensive Care, Maastricht University Medical Center+, P. Debyelaan 25, P.O. Box 5800, Maastricht, 6202, AZ, The Netherlands. S.heines@…. Hauptthemen laut MEDLINE: COVID-19, Electric Impedance, Positive-Pressure Respiration, Respiration, Artificial. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

There is no universally accepted method for positive end expiratory pressure (PEEP) titration approach for patients on spontaneous mechanical ventilation (SMV). Electrical impedance tomography (EIT) guided PEEP-titration has shown promising results in controlled mechanical ventilation (CMV), current implemented algorithm for PEEP titration (based on regional compliance measurements) is not applicable in SMV. Regional peak flow (RPF, defined as the highest inspiratory flow rate based on EIT at a certain PEEP level) is a new method for quantifying regional lung mechanics designed for SMV. The objective is to study whether RPF by EIT is a feasible method for PEEP titration during SMV. Single EIT measurements were performed in COVID-19 ARDS patients on SMV. Clinical (i.e., tidal volume, airway occlusion pressure, end-tidal CO 2 ) and mechanical (cyclic alveolar recruitment, recruitment, cumulative overdistension (OD), cumulative collapse (CL), pendelluft, and PEEP) outcomes were determined by EIT at several pre-defined PEEP thresholds (1–10% CL and the intersection of the OD and CL curves) and outcomes at all thresholds were compared to the outcomes at baseline PEEP. In total, 25 patients were included. No significant and clinically relevant differences were found between thresholds for tidal volume, end-tidal CO 2 , and P0.1 compared to baseline PEEP; cyclic alveolar recruitment rates changed by -3.9% to -37.9% across thresholds; recruitment rates ranged from − 49.4% to + 79.2%; cumulative overdistension changed from − 75.9% to + 373.4% across thresholds; cumulative collapse changed from 0% to -94.3%; PEEP levels from 10 up to 14 cmH 2 O were observed across thresholds compared to baseline PEEP of 10 cmH 2 O. A threshold of approximately 5% cumulative collapse yields the optimum compromise between all clinical and mechanical outcomes. EIT-guided PEEP titration by the RPF approach is feasible and is linked to improved overall lung mechanics) during SMV using a threshold of approximately 5% CL. However, the long-term clinical safety and effect of this approach remain to be determined.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

COVID-19Electric ImpedancePositive-Pressure RespirationRespiration, ArtificialRespiratory Distress SyndromeTomographyAdultAgedFemaleHumansMaleMiddle AgedAlgorithmsCohort StudiesLungRespiratory MechanicsTidal Volume

Stichwörter der Autor:innen

ARDSAirway occlusion pressureElectrical impedance tomographyPendelluftPositive end-expiratory pressureRegional peak flowSpontaneous ventilation

Autor:innen und Institutionen

  • Department of Intensive Care, Maastricht University Medical Center+, P. Debyelaan 25, P.O. Box 5800, Maastricht, 6202, AZ, The Netherlands. S.heines@mumc.nl.
  • Department of Intensive Care, Maastricht University Medical Center+, P. Debyelaan 25, P.O. Box 5800, Maastricht, 6202, AZ, The Netherlands.
  • Department of Pulmonology, Medisch Spectrum Twente, Enschede, The Netherlands.
  • Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, P.O. Box 616, Maastricht, 6200 MD, The Netherlands.
  • Care and Public Health Research Institute (CAPHRI), Maastricht University, P.O. Box 616, Maastricht, 6200 MD, The Netherlands.
  • School of Nutrition and Translational Research in Metabolism (NUTRIM), Maastricht University, P.O. Box 616, Maastricht, 6200 MD, The Netherlands.

ORCID-Profile: S J H Heines, S A M de Jongh, F H C de Jongh, I C C van der Horst, B C T van Bussel, D C J J Bergmans

Zitieren

APA

Heines, S. J. H., de Jongh, S. A. M., de Jongh, F. H. C., Segers, R. P. J., Gilissen, K. M. H., van der Horst, I. C. C., van Bussel, B. C. T., & Bergmans, D. C. J. J. (2024). A novel positive end-expiratory pressure titration using electrical impedance tomography in spontaneously breathing acute respiratory distress syndrome patients on mechanical ventilation: an observational study from the MaastrICCht cohort. Journal of Clinical Monitoring and Computing, 39(1), 127-139. https://doi.org/10.1007/s10877-024-01212-8

Vancouver

Heines SJH, de Jongh SAM, de Jongh FHC, Segers RPJ, Gilissen KMH, van der Horst ICC, et al. A novel positive end-expiratory pressure titration using electrical impedance tomography in spontaneously breathing acute respiratory distress syndrome patients on mechanical ventilation: an observational study from the MaastrICCht cohort. Journal of Clinical Monitoring and Computing. 2024;39(1):127-139. doi:10.1007/s10877-024-01212-8

BibTeX
@article{Heines2024,
  author = {Heines, S J H and de Jongh, S A M and de Jongh, F H C and Segers, R P J and Gilissen, K M H and van der Horst, I C C and van Bussel, B C T and Bergmans, D C J J},
  title = {A novel positive end-expiratory pressure titration using electrical impedance tomography in spontaneously breathing acute respiratory distress syndrome patients on mechanical ventilation: an observational study from the MaastrICCht cohort},
  journal = {Journal of Clinical Monitoring and Computing},
  year = {2024},
  volume = {39},
  number = {1},
  pages = {127--139},
  doi = {10.1007/s10877-024-01212-8}
}
Kostenlos starten →