Fachartikel in der Zeitschrift Journal of Endourology, online erschienen am 01.11.2023. Verfasst von Ben H Chew und 6 weiteren Autor:innen. Beteiligte Einrichtung: The Stone Centre at Vancouver General Hospital, Department of Urologic Sciences, University of British Columbia, Vancouver, British Columbia, Canada. Hauptthemen laut MEDLINE: Ureteroscopes, Ureter. Die Arbeit wurde bisher 45-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Intrarenal pressure is emerging as an important monitoring parameter during flexible ureteroscopy (fURS). We measure how intraoperative conditions affect intrarenal pressure using a novel pressure sensing ureteroscope.

Methods

The LithoVue Elite (LVE) single-use digital flexible ureteroscope (Boston Scientific) is the first commercial ureteroscope that senses pressure at its tip. LVE was used in a porcine model to measure intrarenal pressure with and without a ureteral access sheath (UAS) with various sizes and placement locations, irrigation methods, and working channel accessories. LVE pressure accuracy was measured in a bench model. This abstract shows the least-square means from multiway analysis of variances used for analysis.

Results

Intrarenal pressures were the highest without a UAS (64 mm Hg), followed by the 11/13 UAS (51 mm Hg) and the 12/14 and 13/15, which were not statistically different (39–40 mm Hg). The pressures were highest with UASs placed at the ureteropelvic junction (61 mm Hg), and lowest if placed in the renal pelvis (24 mm Hg). Irrigation methods showed the highest pressures with syringe (57 mm Hg), while irrigation bags (pressurized at 150–300 mm Hg) produced 43 to 46 mm Hg and 25 mm Hg when applied with 80 cm of gravity. Placing a 200 μm laser fiber reduced pressures from 44 to 41 mm Hg. Finally, the bench model showed that LVE was 96% accurate up to 300 mm Hg.

Conclusion

Intrarenal pressure significantly varied based on UAS sizes, placement, and irrigation methods. Accordingly, fURS with LVE is poised to be an invaluable tool for clinical decision-making and future studies of intrarenal pressure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

UreteroscopesUreterSwineAnimalsUreteroscopyPressureTherapeutic Irrigation

Stichwörter der Autor:innen

LithoVue Eliteintrarenal pressureureteral access sheathureterorenoscopyurolithiasis

Autor:innen und Institutionen

  • The Stone Centre at Vancouver General Hospital, Department of Urologic Sciences, University of British Columbia, Vancouver, British Columbia, Canada.
  • Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Clumbia, Canada.
  • Department of Urology, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.
  • Department of Urology, Marien Hospital Herne, Ruhr-University of Bochum, Herne, Germany.
  • Department of Biomedical Engineering, Unviersity of British Columbia, Vancouver, British Columbia, Canada.
  • Faculty of Medicine, Division of Urology, Centre Hospitalier de l'Université de Montréal, Montréal, Québec, Canada.

ORCID-Profile: Ben H Chew, Roman Herout, Naeem Bhojani

Zitieren

APA

Chew, B. H., Shalabi, N., Herout, R., Reicherz, A., Wong, K. F. V., Searles, K., & Bhojani, N. (2023). Intrarenal Pressure Measured Using a Novel Flexible Ureteroscope with Pressure Sensing Capabilities: A Study of the Effects of Ureteral Access Sheath, Irrigation, and Working Channel Accessories. Journal of Endourology, 37(11), 1200-1208. https://doi.org/10.1089/end.2022.0841

Vancouver

Chew BH, Shalabi N, Herout R, Reicherz A, Wong KFV, Searles K, et al. Intrarenal Pressure Measured Using a Novel Flexible Ureteroscope with Pressure Sensing Capabilities: A Study of the Effects of Ureteral Access Sheath, Irrigation, and Working Channel Accessories. Journal of Endourology. 2023;37(11):1200-1208. doi:10.1089/end.2022.0841

BibTeX
@article{Chew2023,
  author = {Chew, Ben H and Shalabi, Nabil and Herout, Roman and Reicherz, Alina and Wong, K F Victor and Searles, Kyle and Bhojani, Naeem},
  title = {Intrarenal Pressure Measured Using a Novel Flexible Ureteroscope with Pressure Sensing Capabilities: A Study of the Effects of Ureteral Access Sheath, Irrigation, and Working Channel Accessories},
  journal = {Journal of Endourology},
  year = {2023},
  volume = {37},
  number = {11},
  pages = {1200--1208},
  doi = {10.1089/end.2022.0841}
}
Kostenlos starten →