Comparison of Superpulse Thulium Fiber Laser vs Holmium Laser for Ablation of Renal Calculi in an In Vivo Porcine Model
Journal of Endourology · 2023
DOI: 10.1089/end.2022.0445 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Endourology, 2023. Verfasst von Pengbo Jiang und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology and UC Irvine School of Medicine, Irvine, Orange, California, USA. Hauptthemen laut MEDLINE: Kidney Calculi, Lasers, Solid-State, Lithotripsy, Lithotripsy, Laser. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Abstract (Originalsprache)
Introduction and Objectives: We sought to compare the effectiveness and efficiency of the superpulse thulium fiber laser (sTFL to the holmium: yttrium–aluminum–garnet [Ho:YAG] laser for ureteroscopic “dusting” of implanted renal stones in an in vivo porcine model.
Methods
Twenty-four porcine kidneys (12 juvenile female Yorkshire pigs) were randomized to Ho:YAG or sTFL treatment groups. Canine calcium oxalate stones were scanned with computed tomography to calculate stone volume and stone density; the stones were randomized and implanted into each renal pelvis via an open pyelotomy. In all trials, a 14F, 35 cm ureteral access sheath was placed. With a 9.9F dual lumen flexible ureteroscope, laser lithotripsy was performed using dusting settings: Ho:YAG 200 μm laser fiber at 16 W (0.4 J, 40 Hz) or sTFL 200 μm laser fiber at 16 W (0.2 J, 80 Hz). Lithotripsy continued until no fragments over 1 mm were observed. No stone basketing was performed. Throughout the procedures, intrarenal and renal pelvis temperatures were measured using two percutaneously positioned K-type thermocouples, one in the upper pole calyx and one in the renal pelvis. After the lithotripsy, the ureteropelvic junction was occluded, the kidneys were bivalved, and all residual fragments were collected, dried, weighed, and then measured with an optical laser particle sizer.
Results
Implanted stones were similar in volume and density in both groups. Intraoperative collecting system temperatures were similar for both groups (all
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Urology and UC Irvine School of Medicine, Irvine, Orange, California, USA.
- Department of Medicine and Program in Public Health, UC Irvine School of Medicine, Irvine, Orange, California, USA.
Zitieren
APA
Jiang, P., Okhunov, Z., Afyouni, A. S., Ali, S., Hosseini Sharifi, S. H., Bhatt, R., Brevik, A., Ayad, M., Larson, K., Osann, K., Patel, R. M., Landman, J., & Clayman, R. V. (2023). Comparison of Superpulse Thulium Fiber Laser vs Holmium Laser for Ablation of Renal Calculi in an In Vivo Porcine Model. Journal of Endourology. https://doi.org/10.1089/end.2022.0445
Vancouver
Jiang P, Okhunov Z, Afyouni AS, Ali S, Hosseini Sharifi SH, Bhatt R, et al. Comparison of Superpulse Thulium Fiber Laser vs Holmium Laser for Ablation of Renal Calculi in an In Vivo Porcine Model. Journal of Endourology. 2023. doi:10.1089/end.2022.0445
BibTeX
@article{Jiang2023,
author = {Jiang, Pengbo and Okhunov, Zhamshid and Afyouni, Andrew S and Ali, Sohrab and Hosseini Sharifi, Seyed Hossein and Bhatt, Rohit and Brevik, Andrew and Ayad, Maged and Larson, Krista and Osann, Kathryn and Patel, Roshan M and Landman, Jaime and Clayman, Ralph V},
title = {Comparison of Superpulse Thulium Fiber Laser vs Holmium Laser for Ablation of Renal Calculi in an In Vivo Porcine Model},
journal = {Journal of Endourology},
year = {2023},
doi = {10.1089/end.2022.0445}
}