WATTS happening? Evaluation of thermal dose during holmium laser lithotripsy in a high-fidelity anatomic model
World Journal of Urology · 2024
DOI: 10.1007/s00345-024-04821-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift World Journal of Urology, 2024. Verfasst von Christopher Wanderling und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, University of Rochester Medical Center, Rochester, NY, USA. Christopher_Wanderling@urmc.rochester.edu. Hauptthemen laut MEDLINE: Lithotripsy, Laser, Lasers, Solid-State, Lithotripsy. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 21 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To evaluate the thermal profiles of the holmium laser at different laser parameters at different locations in an in vitro anatomic pelvicalyceal collecting system (PCS) model. Laser lithotripsy is the cornerstone of treatment for urolithiasis. With the prevalence of high-powered lasers, stone ablation efficiency has become more pronounced. Patient safety remains paramount during surgery. It is well recognized that the heat generated from laser lithotripsy has the potential to cause thermal tissue damage. METHODS: Utilizing high-fidelity, 3D printed hydrogel models of a PCS with a synthetic BegoStone implanted in the renal pelvis, laser lithotripsy was performed with the Moses 2.0 holmium laser. At a standard power (40 W) and irrigation pressure (100 cm H2O), we evaluated operator duty cycle (ODC) variations with different time-on intervals at four different laser settings. Temperature was measured at two separate locations-at the stone and away from the stone. RESULTS: Temperatures were highest closest to the laser tip with a decrease away from the laser. Fluid temperatures increased with longer laser-on times and higher ODCs. Thermal doses were greater with increased ODCs and the threshold for thermal injury was reached for ODCs of 75% and 100%. CONCLUSION: Temperature generation and thermal dose delivered are greatest closer to the tip of the laser fiber and are not dependent on power alone. Significant temperature differences were noted between four laser settings at a standardized power (40 W). Temperatures can be influenced by a variety of factors, such as laser-on time, operator duty cycle, and location in the PCS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Urology, University of Rochester Medical Center, Rochester, NY, USA. Christopher_Wanderling@urmc.rochester.edu.
- Department of Urology, University of Rochester Medical Center, Rochester, NY, USA.
- Department of Urology, Johns Hopkins University, Baltimore, MD, USA.
Zitieren
APA
Wanderling, C., Saxton, A., Phan, D., Doersch, K., Shepard, L., Schuler, N., Osinski, T., Quarrier, S., & Ghazi, A. (2024). WATTS happening? Evaluation of thermal dose during holmium laser lithotripsy in a high-fidelity anatomic model. World Journal of Urology. https://doi.org/10.1007/s00345-024-04821-9
Vancouver
Wanderling C, Saxton A, Phan D, Doersch K, Shepard L, Schuler N, et al. WATTS happening? Evaluation of thermal dose during holmium laser lithotripsy in a high-fidelity anatomic model. World Journal of Urology. 2024. doi:10.1007/s00345-024-04821-9
BibTeX
@article{Wanderling2024,
author = {Wanderling, Christopher and Saxton, Aaron and Phan, Dennis and Doersch, Karen and Shepard, Lauren and Schuler, Nathan and Osinski, Thomas and Quarrier, Scott and Ghazi, Ahmed},
title = {WATTS happening? Evaluation of thermal dose during holmium laser lithotripsy in a high-fidelity anatomic model},
journal = {World Journal of Urology},
year = {2024},
doi = {10.1007/s00345-024-04821-9}
}
EUVIMED