EUVIMEDEUVIMED entdecken
Crossref

Automated ventricular and midline segmentation in cranial ultrasound with metrology

Jaswant Vemulapalli iD, Nicholus Vaughan iD

Biomedical Physics & Engineering Express · 01.08.2026 · 12 (4) · 045039

DOI: 10.1088/2057-1976/ae8bb7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Physics & Engineering Express, online erschienen am 27.07.2026. Verfasst von Jaswant Vemulapalli und 1 weiteren Autor:innen. Beteiligte Einrichtung: Research and Development, Longeviti Neuro Solutions, 2424 Distillery St., Floor 4, Baltimore, MD 21230, United States of America. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Cerebral Ventricles, Brain, Skull. Die Arbeit nennt 16 Literaturangaben. Gefördert von: Longeviti Neuro Solutions.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ultrasound imaging through sonolucent cranial implants is an emerging modality for post-neurosurgical monitoring of the adult brain, but quantitative interpretation remains challenging due to speckle, attenuation, shadowing, and the difficulty of consistently delineating thin anatomical landmarks. We present a deep learning system developed at Longeviti Neuro Solutions for segmenting key intracranial structures–the ipsilateral and contralateral lateral ventricles and the cranial midline–in coronal-plane adult cranial ultrasound images from patients with Longeviti ClearFit ® Acoustic Brain Interface (ABI) TM implants. The dataset comprises 457 proprietary, de-identified ultrasound frames with known pixel spacing, annotated in CVAT with ventricle and midline labels. We benchmark multiple encoder–decoder segmentation architectures and address severe class imbalance using class-weighted optimization with Dice and midline-focused focal-Tversky terms, followed by horizontal-flip test-time averaging. The best-performing configuration achieved a foreground macro Dice of 0.856 on a held-out test set, with Dice values of 0.926, 0.921, and 0.720 for the contralateral ventricle, ipsilateral ventricle, and midline, respectively. Finally, predicted masks are converted into geometry-based metrology overlays by estimating maximal perpendicular ventricle spans and ventricle-to-midline distances. These outputs provide standardized, millimeter-calibrated measurement visualizations for downstream review and future clinical validation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Processing, Computer-AssistedCerebral VentriclesBrainSkullHumansUltrasonographyAlgorithmsDeep Learning

Stichwörter der Autor:innen

U-Netcranial ultrasounddeep learninglateral ventriclesmedical image segmentationmetrologymidline detection

Autor:innen und Institutionen

  • Research and Development, Longeviti Neuro Solutions, 2424 Distillery St., Floor 4, Baltimore, MD 21230, United States of America.

ORCID-Profile: Jaswant Vemulapalli, Nicholus Vaughan

Förderung

  • Longeviti Neuro Solutions

Zitieren

APA

Vemulapalli, J., & Vaughan, N. (2026). Automated ventricular and midline segmentation in cranial ultrasound with metrology. Biomedical Physics & Engineering Express, 12(4), 045039. https://doi.org/10.1088/2057-1976/ae8bb7

Vancouver

Vemulapalli J, Vaughan N. Automated ventricular and midline segmentation in cranial ultrasound with metrology. Biomedical Physics & Engineering Express. 2026;12(4):045039. doi:10.1088/2057-1976/ae8bb7

BibTeX
@article{Vemulapalli2026,
  author = {Vemulapalli, Jaswant and Vaughan, Nicholus},
  title = {Automated ventricular and midline segmentation in cranial ultrasound with metrology},
  journal = {Biomedical Physics & Engineering Express},
  year = {2026},
  volume = {12},
  number = {4},
  pages = {045039},
  doi = {10.1088/2057-1976/ae8bb7}
}
Kostenlos starten →