EUVIMEDEUVIMED entdecken
Crossref

Monte Carlo simulations to evaluate geometric variations of a new Iodine-125 seed

Henrique Santos de Chico iD, Lucas Verdi Angelocci iD, Paula Cristina Guimarães Antunes iD, Carla Daruich de Souza, Carlos Alberto Zeituni, Sabrina Spigaroli Sgrignoli, Maria Elisa Chuery Martins Rostelato iD

Biomedical Physics & Engineering Express · 2026

DOI: 10.1088/2057-1976/ae43ef ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Physics & Engineering Express, 2026. Verfasst von Henrique Santos de Chico und 6 weiteren Autor:innen. Beteiligte Einrichtung: Nuclear and Energy Research Institute, IPEN-CNEN, 05508-000, São Paulo, Brazil. Hauptthemen laut MEDLINE: Iodine Radioisotopes, Monte Carlo Method, Brachytherapy. Die Arbeit nennt 21 Literaturangaben. Gefördert von: Conselho Nacional de Desenvolvimento Científico e Tecnológico, IPEN/CNEN, Centros de Pesquisa, Inovação e Difusão, Fundação Amazônia Paraense de Amparo à Pesquisa.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The Nuclear and Energy Research Institute and the National Nuclear Energy Commission (IPEN-CNEN/SP) are developing a new Iodine-125 seed for use in brachytherapy. The manufacturing process includes cutting the titanium tube, welding the ends, and performing leak tests. Seed approval is based on a microscopic analysis of its external geometry. The dosimetric methodology follows Task Group 43 (TG-43), which adopts the Monte Carlo method as the standard simulation technique. However, TG-43 does not account for geometric variations that may occur during the manufacturing process. This study investigated two types of variation: (1) the seed width after welding, and (2) the random positions that the core may assume within the seed. A total of 100 simulations were performed for each variation. The width was measured experimentally using a caliper, after welding, while the core position was modeled using a random number generator, since it is not feasible to measure it directly. These values were used to generate 201 input files for simulations in MCNP 6.2: 100 for each investigated parameter and one for the reference geometry (IPEN-CNEN/SP seed). The results were analyzed using MATLAB through bidimensional matrices of 101 × 101 points. For each point in the matrix, the mean, standard deviation, relative difference (compared to the reference geometry), and Type A uncertainty were calculated. The main results were: a standard deviation of 0.6% and a relative difference of 11% for the seed width; and a standard deviation of 50% and a relative difference of 25% for the core position. The Type A uncertainty was below 0.3% in all cases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Iodine RadioisotopesMonte Carlo MethodBrachytherapyComputer SimulationHumansRadiotherapy DosageRadiometryRadiotherapy Planning, Computer-Assisted

Stichwörter der Autor:innen

brachytherapydosimetryradiotherapy

Substanzen

Iodine RadioisotopesIodine-125

Autor:innen und Institutionen

  • Nuclear and Energy Research Institute, IPEN-CNEN, 05508-000, São Paulo, Brazil.
  • Hospital Israelita Albert Einstein, 0562-900, São Paulo, Brazil.

ORCID-Profile: Henrique Santos de Chico, Lucas Verdi Angelocci, Paula Cristina Guimarães Antunes, Maria Elisa Chuery Martins Rostelato

Förderung

  • Conselho Nacional de Desenvolvimento Científico e Tecnológico
  • IPEN/CNEN
  • Centros de Pesquisa, Inovação e Difusão, Fundação Amazônia Paraense de Amparo à Pesquisa

Zitieren

APA

de Chico, H. S., Angelocci, L. V., Antunes, P. C. G., de Souza, C. D., Zeituni, C. A., Sgrignoli, S. S., & Rostelato, M. E. C. M. (2026). Monte Carlo simulations to evaluate geometric variations of a new Iodine-125 seed. Biomedical Physics & Engineering Express. https://doi.org/10.1088/2057-1976/ae43ef

Vancouver

de Chico HS, Angelocci LV, Antunes PCG, de Souza CD, Zeituni CA, Sgrignoli SS, et al. Monte Carlo simulations to evaluate geometric variations of a new Iodine-125 seed. Biomedical Physics & Engineering Express. 2026. doi:10.1088/2057-1976/ae43ef

BibTeX
@article{deChico2026,
  author = {de Chico, Henrique Santos and Angelocci, Lucas Verdi and Antunes, Paula Cristina Guimarães and de Souza, Carla Daruich and Zeituni, Carlos Alberto and Sgrignoli, Sabrina Spigaroli and Rostelato, Maria Elisa Chuery Martins},
  title = {Monte Carlo simulations to evaluate geometric variations of a new Iodine-125 seed},
  journal = {Biomedical Physics & Engineering Express},
  year = {2026},
  doi = {10.1088/2057-1976/ae43ef}
}