Monte Carlo simulations to evaluate geometric variations of a new Iodine-125 seed
Biomedical Physics & Engineering Express · 2026
DOI: 10.1088/2057-1976/ae43ef ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Physics & Engineering Express, 2026. Verfasst von Henrique Santos de Chico und 6 weiteren Autor:innen. Beteiligte Einrichtung: Nuclear and Energy Research Institute, IPEN-CNEN, 05508-000, São Paulo, Brazil. Hauptthemen laut MEDLINE: Iodine Radioisotopes, Monte Carlo Method, Brachytherapy. Die Arbeit nennt 21 Literaturangaben. Gefördert von: Conselho Nacional de Desenvolvimento Científico e Tecnológico, IPEN/CNEN, Centros de Pesquisa, Inovação e Difusão, Fundação Amazônia Paraense de Amparo à Pesquisa.
Abstract (Originalsprache)
The Nuclear and Energy Research Institute and the National Nuclear Energy Commission (IPEN-CNEN/SP) are developing a new Iodine-125 seed for use in brachytherapy. The manufacturing process includes cutting the titanium tube, welding the ends, and performing leak tests. Seed approval is based on a microscopic analysis of its external geometry. The dosimetric methodology follows Task Group 43 (TG-43), which adopts the Monte Carlo method as the standard simulation technique. However, TG-43 does not account for geometric variations that may occur during the manufacturing process. This study investigated two types of variation: (1) the seed width after welding, and (2) the random positions that the core may assume within the seed. A total of 100 simulations were performed for each variation. The width was measured experimentally using a caliper, after welding, while the core position was modeled using a random number generator, since it is not feasible to measure it directly. These values were used to generate 201 input files for simulations in MCNP 6.2: 100 for each investigated parameter and one for the reference geometry (IPEN-CNEN/SP seed). The results were analyzed using MATLAB through bidimensional matrices of 101 × 101 points. For each point in the matrix, the mean, standard deviation, relative difference (compared to the reference geometry), and Type A uncertainty were calculated. The main results were: a standard deviation of 0.6% and a relative difference of 11% for the seed width; and a standard deviation of 50% and a relative difference of 25% for the core position. The Type A uncertainty was below 0.3% in all cases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Nuclear and Energy Research Institute, IPEN-CNEN, 05508-000, São Paulo, Brazil.
- Hospital Israelita Albert Einstein, 0562-900, São Paulo, Brazil.
ORCID-Profile: Henrique Santos de Chico, Lucas Verdi Angelocci, Paula Cristina Guimarães Antunes, Maria Elisa Chuery Martins Rostelato
Förderung
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
- IPEN/CNEN
- Centros de Pesquisa, Inovação e Difusão, Fundação Amazônia Paraense de Amparo à Pesquisa
Zitieren
APA
de Chico, H. S., Angelocci, L. V., Antunes, P. C. G., de Souza, C. D., Zeituni, C. A., Sgrignoli, S. S., & Rostelato, M. E. C. M. (2026). Monte Carlo simulations to evaluate geometric variations of a new Iodine-125 seed. Biomedical Physics & Engineering Express. https://doi.org/10.1088/2057-1976/ae43ef
Vancouver
de Chico HS, Angelocci LV, Antunes PCG, de Souza CD, Zeituni CA, Sgrignoli SS, et al. Monte Carlo simulations to evaluate geometric variations of a new Iodine-125 seed. Biomedical Physics & Engineering Express. 2026. doi:10.1088/2057-1976/ae43ef
BibTeX
@article{deChico2026,
author = {de Chico, Henrique Santos and Angelocci, Lucas Verdi and Antunes, Paula Cristina Guimarães and de Souza, Carla Daruich and Zeituni, Carlos Alberto and Sgrignoli, Sabrina Spigaroli and Rostelato, Maria Elisa Chuery Martins},
title = {Monte Carlo simulations to evaluate geometric variations of a new Iodine-125 seed},
journal = {Biomedical Physics & Engineering Express},
year = {2026},
doi = {10.1088/2057-1976/ae43ef}
}
EUVIMED