EUVIMEDEUVIMED entdecken
EvaluationsstudieOpen Access · CC BY 4.0

Evaluation of dose calculation method with a combination of Monte Carlo method and removal-diffusion equation in heterogeneous geometry for boron neutron capture therapy

Mai Nojiri iD, Takushi Takata iD, Akinori Sasaki, Yuki Tamari, Nishiki Matsubayashi, Naonori Hu iD, Yoshinori Sakurai, Minoru Suzuki, Hiroki Tanaka iD

Biomedical Physics & Engineering Express · 2025

DOI: 10.1088/2057-1976/ada7fe ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Biomedical Physics & Engineering Express, 2025. Verfasst von Mai Nojiri und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Engineering, Graduate School of Engineering, Kyoto University, Kyoto daigaku-katsura, Nishikyo-ku, Kyoto, 615-8530, Japan. Hauptthemen laut MEDLINE: Monte Carlo Method, Boron Neutron Capture Therapy, Radiotherapy Planning, Computer-Assisted. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, Support for Pioneering Research Initiated by the Next Generation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Clinical research in boron neutron capture therapy (BNCT) has been conducted worldwide. Currently, the Monte Carlo (MC) method is the only dose calculation algorithm implemented in the treatment planning system for the clinical treatment of BNCT. We previously developed the MC-RD calculation method, which combines the MC method and the removal-diffusion (RD) equation, for fast dose calculation in BNCT. This study aimed to verify the partial-MC-RD calculation method, which utilizes the MC-RD calculation method for a portion of the entire neutron energy range, in terms of calculation accuracy and time as the dose calculation method. We applied the partial-MC-RD calculation method to calculate the total dose for head phantom, comprising soft tissue, brain tissue, and bone. The calculation time and accuracy were evaluated based on the full-MC method. Our accuracy verifications indicated that the partial-MC-RD calculation was mostly comparable with full-MC calculation in the accuracy. However, the assumptions and approximation used in the RD calculation mainly occurred the discrepancy from the full-MC calculation result. Additionally, the partial-MC-RD calculation reduced the time required to approximately 45% for the irradiation to the top and cheek region of head phantom, compared to the full-MC calculation. In conclusion, the MC-RD calculation method can be the basis of a fast dose calculation method in BNCT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Monte Carlo MethodBoron Neutron Capture TherapyRadiotherapy Planning, Computer-AssistedHumansRadiotherapy DosagePhantoms, ImagingAlgorithmsDiffusionComputer Simulation

Autor:innen und Institutionen

  • Department of Nuclear Engineering, Graduate School of Engineering, Kyoto University, Kyoto daigaku-katsura, Nishikyo-ku, Kyoto, 615-8530, Japan.
  • Institute for Integrated Radiation and Nuclear Science, Kyoto University, 2 Asashiro-nishi, Kumatori-cho, Sennan-gun, Osaka, 590-0494, Japan.
  • Kansai BNCT Medical Center, Osaka Medical and Pharmaceutical University, 2-7 Daigaku-machi, Takatsuki-shi, Osaka, 569-8686, Japan.
  • School of Medical Sciences, Fujita Health University, 1-98 Dengakugakubo, Kutsukakecho, Toyoake-shi, Aichi, 470-1192, Japan.

ORCID-Profile: Mai Nojiri, Takushi Takata, Naonori Hu, Hiroki Tanaka

Förderung

  • Japan Society for the Promotion of Science
  • Support for Pioneering Research Initiated by the Next Generation

Zitieren

APA

Nojiri, M., Takata, T., Sasaki, A., Tamari, Y., Matsubayashi, N., Hu, N., Sakurai, Y., Suzuki, M., & Tanaka, H. (2025). Evaluation of dose calculation method with a combination of Monte Carlo method and removal-diffusion equation in heterogeneous geometry for boron neutron capture therapy. Biomedical Physics & Engineering Express. https://doi.org/10.1088/2057-1976/ada7fe

Vancouver

Nojiri M, Takata T, Sasaki A, Tamari Y, Matsubayashi N, Hu N, et al. Evaluation of dose calculation method with a combination of Monte Carlo method and removal-diffusion equation in heterogeneous geometry for boron neutron capture therapy. Biomedical Physics & Engineering Express. 2025. doi:10.1088/2057-1976/ada7fe

BibTeX
@article{Nojiri2025,
  author = {Nojiri, Mai and Takata, Takushi and Sasaki, Akinori and Tamari, Yuki and Matsubayashi, Nishiki and Hu, Naonori and Sakurai, Yoshinori and Suzuki, Minoru and Tanaka, Hiroki},
  title = {Evaluation of dose calculation method with a combination of Monte Carlo method and removal-diffusion equation in heterogeneous geometry for boron neutron capture therapy},
  journal = {Biomedical Physics & Engineering Express},
  year = {2025},
  doi = {10.1088/2057-1976/ada7fe}
}
Kostenlos starten →