Non-thermal argon plasma enhances wettability of Ti–6Al–4V biomaterial surfaces without detectable elemental alteration
Materials Research Express · 13.11.2026 · 13 (21) · 215402
DOI: 10.1088/2053-1591/aebea2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials Research Express, online erschienen am 13.11.2026. Verfasst von Elthon Luis Pupe de Morais E Silva und 6 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This in vitro study evaluated whether non-thermal argon plasma could improve the wettability of Grade 5 titanium alloy (Ti–6Al–4V) surfaces without producing detectable changes in elemental composition. Ninety commercially sourced Ti–6Al–4V discs were allocated to one of three surface conditions: machined, nitric acid-treated, or hydrochloric acid-treated. For wettability analysis, each surface condition was evaluated either without plasma treatment or after 60 s of non-thermal argon plasma exposure at 22 °C, with 13 independent discs per subgroup. Water contact angle was measured using the sessile-drop method, and the mean of the left and right contact angles was used as the specimen-level outcome. Surface morphology and elemental composition were evaluated qualitatively by scanning electron microscopy (SEM) and energy-dispersive x-ray spectroscopy (EDX) before plasma exposure and immediately and at 30 and 60 min after treatment. Argon plasma significantly reduced the water contact angle in all surface groups ( p < 0.0001), indicating a marked increase in wettability. Mean contact angle decreased from 162.6° to 32.74° on machined surfaces, from 150.5° to 12.96° on nitric acid-treated surfaces, and from 110.0° to 21.87° on hydrochloric acid-treated surfaces. Plasma-treated acid-conditioned surfaces exhibited lower contact angles than plasma-treated machined surfaces. SEM indicated that plasma exposure made pre-existing topographic features more visually distinct, particularly on acid-treated surfaces, whereas EDX revealed no appreciable changes in elemental composition. These findings support non-thermal argon plasma as a short-term surface-activation strategy for Ti–6Al–4V biomaterials; however, the durability and biological relevance of this effect require further investigation.
Zitieren
APA
Silva, E. L. P. D. M. E., Júnior, V. V. B. F., Costa, D. R., Pollon, T. C., Cortelli, S. C., Silva, J. M. F. D., & Romeiro, R. D. L. (2026). Non-thermal argon plasma enhances wettability of Ti–6Al–4V biomaterial surfaces without detectable elemental alteration. Materials Research Express, 13(21), 215402. https://doi.org/10.1088/2053-1591/aebea2
Vancouver
Silva ELPDME, Júnior VVBF, Costa DR, Pollon TC, Cortelli SC, Silva JMFD, et al. Non-thermal argon plasma enhances wettability of Ti–6Al–4V biomaterial surfaces without detectable elemental alteration. Materials Research Express. 2026;13(21):215402. doi:10.1088/2053-1591/aebea2
BibTeX
@article{Silva2026,
author = {Silva, Elthon Luis Pupe de Morais E and Júnior, Virgílio Vilas Boas Fernandes and Costa, Davidson Ribeiro and Pollon, Talissa Caroline and Cortelli, Sheila Cavalca and Silva, João Maurício Ferraz da and Romeiro, Rogério de Lima},
title = {Non-thermal argon plasma enhances wettability of Ti–6Al–4V biomaterial surfaces without detectable elemental alteration},
journal = {Materials Research Express},
year = {2026},
volume = {13},
number = {21},
pages = {215402},
doi = {10.1088/2053-1591/aebea2}
}
EUVIMED