Bioinspired functionally graded TPU gyroid structures for intervertebral disc replacement fabricated by multimaterial 3D printing
Biomedical Materials · 01.10.2026 · 21 (5) · 055007
DOI: 10.1088/1748-605x/aea047 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Materials, online erschienen am 16.09.2026. Verfasst von Leandro Hippel und 7 weiteren Autor:innen. Beteiligte Einrichtung: G.E.R.N. Center for Tissue Replacement, Regeneration & Neogenesis, Department of Orthopedics and Trauma Surgery, Medical Center-Albert-Ludwigs-Univer…. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Polyurethanes, Intervertebral Disc, Total Disc Replacement. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Degenerative disc disease remains a primary cause of chronic back pain, yet current surgical treatments are often limited by the mechanical mismatch between implants and native intervertebral disc (IVD) tissue. This study investigates additively manufactured functionally graded Gyroid structures based on thermoplastic polyurethane (TPU) as biomimetic IVD replacements, focusing on the influence of geometry and material gradients on mechanical performance. Gyroid-based constructs were fabricated by multi-material fused filament fabrication using TPU filaments of different stiffness. Their mechanical performance was evaluated under static and dynamic compressive loading. Finite element analysis was performed to investigate stress distribution within the Gyroid architecture, while micro-computed tomography (µCT) was used to assess manufacturing-related defects and structural integrity before and after 700 000 loading cycles. All investigated structures exhibited stable and reproducible mechanical behavior. However, only a single geometric configuration reached the targeted physiological load range of 4000–8000 N, irrespective of the material combination. The incorporation of an additional compliant TPU phase did not significantly alter the global force–deformation response compared with two-material configurations, indicating that structural geometry predominantly governs the compressive mechanical behavior. Dynamic testing demonstrated consistent damping capacities of approximately 20% across all configurations together with stable stiffness, storage modulus, and loss modulus during fatigue loading. Finite element analysis revealed homogeneous load distribution with localized stress concentrations at the curved Gyroid junctions. Quantitative µCT analysis showed no measurable increase in micro-porosity, void fraction, or interfacial defects after 600 000 loading cycles. The findings demonstrate that the mechanical performance of TPU-based Gyroid IVD constructs is primarily governed by architectural design rather than material gradients under compressive loading. The combined experimental, numerical, and µCT analyses confirm the mechanical robustness and structural stability of the proposed functionally graded Gyroid structures, highlighting architecture-driven design as a promising strategy for mechanically compatible IVD replacements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- G.E.R.N. Center for Tissue Replacement, Regeneration & Neogenesis, Department of Orthopedics and Trauma Surgery, Medical Center-Albert-Ludwigs-University of Freiburg, Faculty of Medicine, Albert-Ludwigs-University of Fr…
- Biomechanics, Offenburg University, Badstraße 24, 77652 Offenburg, Germany.
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, Faculty of Medicine, University Medical Center, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Freiburg, Germany.
- Department of Orthopedics and Trauma Surgery, Medical Center-Albert-Ludwigs-University of Freiburg, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Hugstetter Straße 55, 79106 Freiburg, Germany.
- Department of Orthopedic Surgery and Traumatology, Odense University Hospital, 5000 Odense, Denmark.
ORCID-Profile: Leandro Hippel, Martin Peter Pichotka, Dirk Velten, Sunil Shetty, Bernd Rolauffs, Melanie Lynn Hart, Hagen Schmal, Michael Seidenstuecker
Zitieren
APA
Hippel, L., Pichotka, M. P., Velten, D., Shetty, S., Rolauffs, B., Hart, M. L., Schmal, H., & Seidenstuecker, M. (2026). Bioinspired functionally graded TPU gyroid structures for intervertebral disc replacement fabricated by multimaterial 3D printing. Biomedical Materials, 21(5), 055007. https://doi.org/10.1088/1748-605x/aea047
Vancouver
Hippel L, Pichotka MP, Velten D, Shetty S, Rolauffs B, Hart ML, et al. Bioinspired functionally graded TPU gyroid structures for intervertebral disc replacement fabricated by multimaterial 3D printing. Biomedical Materials. 2026;21(5):055007. doi:10.1088/1748-605x/aea047
BibTeX
@article{Hippel2026,
author = {Hippel, Leandro and Pichotka, Martin Peter and Velten, Dirk and Shetty, Sunil and Rolauffs, Bernd and Hart, Melanie Lynn and Schmal, Hagen and Seidenstuecker, Michael},
title = {Bioinspired functionally graded TPU gyroid structures for intervertebral disc replacement fabricated by multimaterial 3D printing},
journal = {Biomedical Materials},
year = {2026},
volume = {21},
number = {5},
pages = {055007},
doi = {10.1088/1748-605x/aea047}
}
EUVIMED