EUVIMEDEUVIMED entdecken
Scoping ReviewOpen Access · CC BY 4.0

Single-channel EEG denoising and artifact removal: a systematic scoping review of methods, benchmarking, and reproducibility

Usman Qamar Shaikh iD, Anubha Manju Kalra iD, Andrew Lowe iD, Imran Khan Niazi iD

Journal of Neural Engineering · 2026

DOI: 10.1088/1741-2552/aeb0ce ↗

Kurz gefasst

Scoping Review in der Zeitschrift Journal of Neural Engineering, 2026. Verfasst von Usman Qamar Shaikh und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biomedical Technologies, Auckland University of Technology, Auckland 1010, New Zealand. Hauptthemen laut MEDLINE: Artifacts, Electroencephalography, Benchmarking. Die Arbeit nennt 225 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Auckland University of Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective. Single-channel and wearable electroencephalography (EEG) reduce acquisition burden but limit the spatial information available to conventional multichannel artifact-removal methods. We conducted a systematic scoping review of single-channel-compatible EEG artifact removal, linking method operation with artifact coverage, evaluation design, generalization, deployment, comparison, and reproducibility. Approach. Database and citation searches through 15 2026 identified 178 articles describing 199 method variants. For learned methods, 303 reported model-dataset evaluations were also examined for data independence, generalization, and deployment. Main results. Most variants were reference-free at inference (179/199), while 13 used a non-neural auxiliary reference. Methods spanned seven operating paradigms, including decomposition, transformed source separation, adaptive correction, and learned reconstruction. Ocular and muscle artifacts were evaluated most often, and 38/178 articles tested simultaneous or overlapping mixtures. Across 380 dataset uses, evaluation centered on controlled signal reconstruction. Known-target fidelity was reported for 170/199 variants, compared with 21 for clean-input or non-artifact signal comparison, 32 for contaminated downstream utility, and three for clean-input downstream non-degradation. Among 81 learned variants, 18 reported source-trained application to an external dataset, device, or site; only 31/303 evaluations explicitly separated test windows or epochs, clean sources, and artifact sources from training. No measured deployment evidence was reported for 122/199 variants. Public method resources were available for 21 variants, while trained weights and explicit licenses were uncommon. Significance. The review provides a framework for selecting datasets, metrics, comparators, and implementations, and for distinguishing reconstruction, neural preservation, transfer, and wearable deployment evidence

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArtifactsElectroencephalographyBenchmarkingHumansReproducibility of ResultsSignal Processing, Computer-Assisted

Stichwörter der Autor:innen

EEG denoisingartifact removalbenchmarkingneural preservationscoping reviewsingle-channel EEGwearable EEG

Autor:innen und Institutionen

  • Institute of Biomedical Technologies, Auckland University of Technology, Auckland 1010, New Zealand.
  • Department of Electrical and Electronic Engineering, School of Engineering Computer and Mathematical Sciences, Auckland University of Technology, Auckland 1010, New Zealand.
  • Department of Mechanical Engineering, School of Engineering Computer and Mathematical Sciences, Auckland University of Technology, Auckland 1010, New Zealand.
  • Centre for Chiropractic Research, New Zealand College of Chiropractic, Auckland 1060, New Zealand.
  • Department of Health Science and Technology, Aalborg University, 9200 Aalborg, Denmark.

ORCID-Profile: Usman Qamar Shaikh, Anubha Manju Kalra, Andrew Lowe, Imran Khan Niazi

Förderung

  • Auckland University of Technology

Zitieren

APA

Shaikh, U. Q., Kalra, A. M., Lowe, A., & Niazi, I. K. (2026). Single-channel EEG denoising and artifact removal: a systematic scoping review of methods, benchmarking, and reproducibility. Journal of Neural Engineering. https://doi.org/10.1088/1741-2552/aeb0ce

Vancouver

Shaikh UQ, Kalra AM, Lowe A, Niazi IK. Single-channel EEG denoising and artifact removal: a systematic scoping review of methods, benchmarking, and reproducibility. Journal of Neural Engineering. 2026. doi:10.1088/1741-2552/aeb0ce

BibTeX
@article{Shaikh2026,
  author = {Shaikh, Usman Qamar and Kalra, Anubha Manju and Lowe, Andrew and Niazi, Imran Khan},
  title = {Single-channel EEG denoising and artifact removal: a systematic scoping review of methods, benchmarking, and reproducibility},
  journal = {Journal of Neural Engineering},
  year = {2026},
  doi = {10.1088/1741-2552/aeb0ce}
}
Kostenlos starten →