Rating by detection: an artifact detection protocol for rating EEG quality with average event duration
Journal of Neural Engineering · 2023
DOI: 10.1088/1741-2552/acbabe ↗Kurz gefasst
Studienprotokoll in der Zeitschrift Journal of Neural Engineering, 2023. Verfasst von Daniel Wȩsierski und 6 weiteren Autor:innen. Beteiligte Einrichtung: Gdańsk University of Technology, Faculty of Electronics, Telecommunications, and Informatics, Gdańsk, Poland. Hauptthemen laut MEDLINE: Signal Processing, Computer-Assisted, Artifacts. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Narodowe Centrum Badań i Rozwoju.
Abstract (Originalsprache)
Objective . Quantitative evaluation protocols are critical for the development of algorithms that remove artifacts from real electroencephalography (EEG) optimally. However, visually inspecting the real EEG to select the top-performing artifact removal pipeline is infeasible while hand-crafted EEG data allow assessing artifact removal configurations only in a simulated environment. This study proposes a novel, principled approach for quantitatively evaluating algorithmically corrected EEG without access to ground truth in real-world conditions. Approach . Our offline evaluation protocol uses a detector to score the presence of artifacts. It computes their average duration, which measures the recovered EEG’s deviation from the modeled background activity with a single score. As we expect the detector to make generalization errors, we employ a generic and configurable Wiener-based artifact removal method to validate the reliability of our detection protocol. Main results . Quantitative experiments extensively compare many Wiener filters and show their consistent rankings agree with their theoretical assumptions and expectations. Significance . The rating-by-detection protocol with the average event duration measure should be of value for EEG practitioners and developers. After removing artifacts from real EEG, the protocol experimentally shows that reliable comparisons between many artifact filtering configurations are possible despite the missing ground-truth neural signals.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Gdańsk University of Technology, Faculty of Electronics, Telecommunications, and Informatics, Gdańsk, Poland.
- Elmiko Biosignals, Warsaw, Poland.
- Department of Children's Neurosurgery, Jagiellonian University Medical College, Cracow, Poland.
ORCID-Profile: Daniel Wȩsierski
Förderung
- Narodowe Centrum Badań i Rozwoju
Zitieren
APA
Wȩsierski, D., Rufuie, M. R., Milczarek, O., Ziembla, W., Ogniewski, P., Kołodziejak, A., & Niedbalski, P. (2023). Rating by detection: an artifact detection protocol for rating EEG quality with average event duration. Journal of Neural Engineering. https://doi.org/10.1088/1741-2552/acbabe
Vancouver
Wȩsierski D, Rufuie MR, Milczarek O, Ziembla W, Ogniewski P, Kołodziejak A, et al. Rating by detection: an artifact detection protocol for rating EEG quality with average event duration. Journal of Neural Engineering. 2023. doi:10.1088/1741-2552/acbabe
BibTeX
@article{Wsierski2023,
author = {Wȩsierski, Daniel and Rufuie, Mehrdad Rahimzadeh and Milczarek, Olga and Ziembla, Wojciech and Ogniewski, Paweł and Kołodziejak, Anna and Niedbalski, Paweł},
title = {Rating by detection: an artifact detection protocol for rating EEG quality with average event duration},
journal = {Journal of Neural Engineering},
year = {2023},
doi = {10.1088/1741-2552/acbabe}
}
EUVIMED