Evaluation of gold helical microwire structure electrode for long-term rodent nerve stimulation
Journal of Neural Engineering · 01.06.2025 · 22 (3) · 036042
DOI: 10.1088/1741-2552/ade18a ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Journal of Neural Engineering, online erschienen am 18.06.2025. Verfasst von Danny V Lam und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States of America. Hauptthemen laut MEDLINE: Gold, Electrodes, Implanted, Sciatic Nerve. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 75 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, National Science Foundation Graduate Research Fellowship Program, National Institute of Biomedical Imaging and Bioengineering.
Abstract (Originalsprache)
Objective. The development of electrodes for chronic peripheral nerve stimulation faces several challenges, including complex compositions, intricate manufacturing processes, and high costs associated with the availability and fabrication of suitable materials. These limitations hinder the accessibility and feasibility of producing effective devices for chronic preclinical studies. This study evaluated the feasibility of a simple-to-manufacture gold helical microwire structure electrode (Au-HMSE) for peripheral nerve stimulation, electromyography (EMG) recording, and preliminary tissue response on the rat sciatic nerve. Approach. Manufactured electrodes were used for up to 8 weeks in rats for nerve stimulation and EMG recordings, with electrode-tissue impedances and motor thresholds measured to assess in vivo stability and feasibility. Evoked motor responses were measured via gastrocnemius muscle activity and ankle torque. Terminal histology was performed at 12 weeks to assess chronic tissue response to the implanted electrodes. Main results. Implanted electrodes with impedances
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States of America.
- Advanced Platform Technology Center, Louis Stokes Cleveland VA Medical Center, Cleveland, OH, United States of America.
- Neuronoff Inc., Cleveland, OH, United States of America.
- Department of Mechanical Engineering and the Neuroscience Institute, Carnegie Mellon University, Pittsburgh, PA, United States of America.
- Rehab Neural Engineering Labs, Departments of Physical Medicine and Rehabilitation and Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States of America.
- Departments of Biomedical Engineering and Anesthesiology, Biointerfaces Institute, University of Michigan, Ann Arbor, MI, United States of America.
ORCID-Profile: Danny V Lam, Kevin Yang, Stephan Nieuwoudt, Doug J Weber, Lee E Fisher, Scott F Lempka, Ashley N Dalrymple, Kip A Ludwig, Andrew J Shoffstall
Förderung
- NIBIB NIH HHS
- National Science Foundation Graduate Research Fellowship Program
- National Institute of Biomedical Imaging and Bioengineering
Zitieren
APA
Lam, D. V., Yang, K., Liu, D. X., Lauricella, A., Gao, Y., Fielding, E. S., Golobish, K., Nieuwoudt, S., Weber, D. J., Fisher, L. E., Lempka, S. F., Dalrymple, A. N., Ludwig, K. A., & Shoffstall, A. J. (2025). Evaluation of gold helical microwire structure electrode for long-term rodent nerve stimulation. Journal of Neural Engineering, 22(3), 036042. https://doi.org/10.1088/1741-2552/ade18a
Vancouver
Lam DV, Yang K, Liu DX, Lauricella A, Gao Y, Fielding ES, et al. Evaluation of gold helical microwire structure electrode for long-term rodent nerve stimulation. Journal of Neural Engineering. 2025;22(3):036042. doi:10.1088/1741-2552/ade18a
BibTeX
@article{Lam2025,
author = {Lam, Danny V and Yang, Kevin and Liu, Derrick X and Lauricella, Anna and Gao, Yingyi and Fielding, Elizabeth S and Golobish, Kyle and Nieuwoudt, Stephan and Weber, Doug J and Fisher, Lee E and Lempka, Scott F and Dalrymple, Ashley N and Ludwig, Kip A and Shoffstall, Andrew J},
title = {Evaluation of gold helical microwire structure electrode for long-term rodent nerve stimulation},
journal = {Journal of Neural Engineering},
year = {2025},
volume = {22},
number = {3},
pages = {036042},
doi = {10.1088/1741-2552/ade18a}
}
EUVIMED