EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Spatially repeatable components from ultrafast ultrasound are associated with motor unit activity in human isometric contractions *

Robin Rohlén iD, Marco Carbonaro iD, Giacinto L Cerone iD, Kristen M Meiburger iD, Alberto Botter iD, Christer Grönlund iD

Journal of Neural Engineering · 2023

DOI: 10.1088/1741-2552/ace6fc ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Neural Engineering, 2023. Verfasst von Robin Rohlén und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Lund University, Lund, Sweden. Hauptthemen laut MEDLINE: Isometric Contraction, Muscle, Skeletal. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Italian Ministry of Universities and Research, Swedish Research Council for Sport Science, Swedish Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective. Ultrafast ultrasound (UUS) imaging has been used to detect intramuscular mechanical dynamics associated with single motor units (MUs). Detecting MUs from ultrasound sequences requires decomposing a velocity field into components, each consisting of an image and a signal. These components can be associated with putative MU activity or spurious movements (noise). The differentiation between putative MUs and noise has been accomplished by comparing the signals with MU firings obtained from needle electromyography (EMG). Here, we examined whether the repeatability of the images over brief time intervals can serve as a criterion for distinguishing putative MUs from noise in low-force isometric contractions. Approach. UUS images and high-density surface EMG (HDsEMG) were recorded simultaneously from 99 MUs in the biceps brachii of five healthy subjects. The MUs identified through HDsEMG decomposition were used as a reference to assess the outcomes of the ultrasound-based components. For each contraction, velocity sequences from the same eight-second ultrasound recording were separated into consecutive two-second epochs and decomposed. To evaluate the repeatability of components’ images across epochs, we calculated the Jaccard similarity coefficient (JSC). JSC compares the similarity between two images providing values between 0 and 1. Finally, the association between the components and the MUs from HDsEMG was assessed. Main results. All the MU-matched components had JSC > 0.38, indicating they were repeatable and accounted for about one-third of the HDsEMG-detected MUs (1.8 ± 1.6 matches over 4.9 ± 1.8 MUs). The repeatable components (JSC > 0.38) represented 14% of the total components (6.5 ± 3.3 components). These findings align with our hypothesis that intra-sequence repeatability can differentiate putative MUs from noise and can be used for data reduction. Significance. This study provides the foundation for developing stand-alone methods to identify MU in UUS sequences and towards real-time imaging of MUs. These methods are relevant for studying muscle neuromechanics and designing novel neural interfaces.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Isometric ContractionMuscle, SkeletalHumansElectromyographyArmHealthy VolunteersMuscle Contraction

Stichwörter der Autor:innen

decompositionelectromyographymotor unitterritoryultrafast ultrasound

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Lund University, Lund, Sweden.
  • Department of Radiation Sciences, Radiation Physics, Biomedical Engineering, Umeå University, Umeå, Sweden.
  • Department of Electronics and Telecommunication, Laboratory for Engineering of the Neuromuscular System (LISiN), Politecnico di Torino, Turin, Italy.
  • PoliToBIOMed Lab, Politecnico di Torino, Turin, Italy.
  • Biolab, Department of Electronics and Telecommunications, Politecnico di Torino, Turin, Italy.

ORCID-Profile: Robin Rohlén, Marco Carbonaro, Giacinto L Cerone, Kristen M Meiburger, Alberto Botter, Christer Grönlund

Förderung

  • Italian Ministry of Universities and Research
  • Swedish Research Council for Sport Science
  • Swedish Research Council

Zitieren

APA

Rohlén, R., Carbonaro, M., Cerone, G. L., Meiburger, K. M., Botter, A., & Grönlund, C. (2023). Spatially repeatable components from ultrafast ultrasound are associated with motor unit activity in human isometric contractions *. Journal of Neural Engineering. https://doi.org/10.1088/1741-2552/ace6fc

Vancouver

Rohlén R, Carbonaro M, Cerone GL, Meiburger KM, Botter A, Grönlund C. Spatially repeatable components from ultrafast ultrasound are associated with motor unit activity in human isometric contractions *. Journal of Neural Engineering. 2023. doi:10.1088/1741-2552/ace6fc

BibTeX
@article{Rohln2023,
  author = {Rohlén, Robin and Carbonaro, Marco and Cerone, Giacinto L and Meiburger, Kristen M and Botter, Alberto and Grönlund, Christer},
  title = {Spatially repeatable components from ultrafast ultrasound are associated with motor unit activity in human isometric contractions *},
  journal = {Journal of Neural Engineering},
  year = {2023},
  doi = {10.1088/1741-2552/ace6fc}
}
Kostenlos starten →