Advanced electrochemical potential monitoring for improved understanding of electrical neurostimulation protocols

Moritz Doering iD, Jochen Kieninger iD, Julian Kübler, Ulrich G Hofmann iD, Stefan J Rupitsch, Gerald A Urban, Andreas Weltin iD

Journal of Neural Engineering · 2023

DOI: 10.1088/1741-2552/acdd9d ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Neural Engineering, 2023. Verfasst von Moritz Doering und 6 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory for Sensors, IMTEK-Department of Microsystems Engineering, University of Freiburg, Freiburg, Germany. Hauptthemen laut MEDLINE: Cochlear Implants, Neural Prostheses, Cochlear Implantation. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bundesministerium für Wirtschaft und Klimaschutz, BrainLinks-BrainTools.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective. Current-controlled neurostimulation is increasingly used in the clinical treatment of neurological disorders and widely applied in neural prostheses such as cochlear implants. Despite its importance, time-dependent potential traces of electrodes during microsecond-scale current pulses, especially with respect to a reference electrode (RE), are not precisely understood. However, this knowledge is critical to predict contributions of chemical reactions at the electrodes, and ultimately electrode stability, biocompatibility, and stimulation safety and efficacy. Approach. We assessed the electrochemistry of neurostimulation protocols in vitro with Pt microelectrodes from millisecond (classical electroanalysis) to microsecond (neurostimulation) timescales. We developed a dual-channel instrumentation amplifier to include a RE in neurostimulation setups. Uniquely, we combined potential measurements with potentiostatic prepolarization to control and investigate the surface status, which is not possible in typical stimulation setups. Main results. We thoroughly validated the instrumentation and highlighted the importance of monitoring individual electrochemical electrode potentials in different configurations of neurostimulation. We investigated electrode processes such as oxide formation and oxygen reduction by chronopotentiometry, bridging the gap between milli- and microsecond timescales. Our results demonstrate how much impact on potential traces the electrode’s initial surface state and electrochemical surface processes have, even on a microsecond scale. Significance. Our unique use of preconditioning in combination with stimulation reveals that interpreting potential traces with respect to electrode processes is misleading without rigorous control of the electrode’s surface state. Especially in vivo , where the microenvironment is unknown, simply measuring the voltage between two electrodes cannot accurately reflect the electrode’s state and processes. Potential boundaries determine charge transfer, corrosion, and alterations of the electrode/tissue interface such as pH and oxygenation, particularly in long-term in vivo use. Our findings are relevant for all use-cases of constant-current stimulation, strongly advocating for electrochemical in situ investigations in many applications like the development of new electrode materials and stimulation methods.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cochlear ImplantsNeural ProsthesesCochlear ImplantationElectrodesMicroelectrodesElectrochemistryPlatinum

Stichwörter der Autor:innen

chronopotentiometryelectrochemistryelectrode potentialneurostimulationplatinumpotentiostat

Substanzen

Platinum

Autor:innen und Institutionen

  • Laboratory for Sensors, IMTEK-Department of Microsystems Engineering, University of Freiburg, Freiburg, Germany.
  • Laboratory for Electrical Instrumentation and Embedded Systems, IMTEK-Department of Microsystems Engineering, University of Freiburg, Freiburg, Germany.
  • BrainLinks-BrainTools Center, University of Freiburg, Freiburg, Germany.
  • Section for Neuroelectronic Systems, Department of Neurosurgery, Medical Center-University of Freiburg, Freiburg, Germany.
  • Faculty of Medicine, University of Freiburg, Freiburg, Germany.

ORCID-Profile: Moritz Doering, Jochen Kieninger, Ulrich G Hofmann, Andreas Weltin

Förderung

  • Bundesministerium für Wirtschaft und Klimaschutz
  • BrainLinks-BrainTools

Zitieren

APA

Doering, M., Kieninger, J., Kübler, J., Hofmann, U. G., Rupitsch, S. J., Urban, G. A., & Weltin, A. (2023). Advanced electrochemical potential monitoring for improved understanding of electrical neurostimulation protocols. Journal of Neural Engineering. https://doi.org/10.1088/1741-2552/acdd9d

Vancouver

Doering M, Kieninger J, Kübler J, Hofmann UG, Rupitsch SJ, Urban GA, et al. Advanced electrochemical potential monitoring for improved understanding of electrical neurostimulation protocols. Journal of Neural Engineering. 2023. doi:10.1088/1741-2552/acdd9d

BibTeX
@article{Doering2023,
  author = {Doering, Moritz and Kieninger, Jochen and Kübler, Julian and Hofmann, Ulrich G and Rupitsch, Stefan J and Urban, Gerald A and Weltin, Andreas},
  title = {Advanced electrochemical potential monitoring for improved understanding of electrical neurostimulation protocols},
  journal = {Journal of Neural Engineering},
  year = {2023},
  doi = {10.1088/1741-2552/acdd9d}
}
Kostenlos starten →