The field sensitivity and inspection area coverage are key factors in developing low magnetic field sensors. A novel approach has been adopted in the parametric controls of a Giant magneto-impedance (GMI) based sensor with a linear array of amorphous microwires. The arrayed configuration displayed an enhanced GMI field sensitivity compared to a single sensor element. The larger footprint of the sensor for inspection due to this arrangement was evidenced from the greater magneto-impedance response towards the external magnetic field. An interesting spatial distribution of magnetic flux in an arrayed configuration of microwires was observed through COMSOL Multiphysics simulation. Joule annealing of the microwires, coupled with the array pattern, enhanced the sensor properties for potential low-field sensing applications. The arrayed sensor displayed a far enhanced signal output compared to a single-element sensor in detecting Earth’s magnetic field, thereby endorsing its scope for low-field sensing applications.
Förderung
- Financial assistance
Zitieren
APA
Das, S., Mahato, D. K., Panda, A. K., Murugaiyan, P., & Roy, R. K. (2025). Impact of parametric controls and spatial flux distribution on the arrayed microwires of a giant magneto-impedance (GMI) sensor. Physica Scripta, 100(7), 075916. https://doi.org/10.1088/1402-4896/add96f
Vancouver
Das S, Mahato DK, Panda AK, Murugaiyan P, Roy RK. Impact of parametric controls and spatial flux distribution on the arrayed microwires of a giant magneto-impedance (GMI) sensor. Physica Scripta. 2025;100(7):075916. doi:10.1088/1402-4896/add96f
BibTeX
@article{Das2025,
author = {Das, Somnath and Mahato, Dev Kumar and Panda, Ashis Kumar and Murugaiyan, Premkumar and Roy, Rajat Kumar},
title = {Impact of parametric controls and spatial flux distribution on the arrayed microwires of a giant magneto-impedance (GMI) sensor},
journal = {Physica Scripta},
year = {2025},
volume = {100},
number = {7},
pages = {075916},
doi = {10.1088/1402-4896/add96f}
}
EUVIMED