EUVIMEDEUVIMED entdecken
Crossref

Magnetic signal scan imaging system based on giant magnetoimpedance (GMI) differential sensor

Tao Yang iD, Zhoulu Yu iD, Xuekui Xi iD, Changjun Jiang iD, Guozhi Chai iD

Review of Scientific Instruments · 01.07.2026 · 97 (7)

DOI: 10.1063/5.0313791 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 24.07.2026. Verfasst von Tao Yang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory for Magnetism and Magnetic Functional Materials of the Ministry of Education, Lanzhou University, Lanzhou 730000, People's Republic of…. Die Arbeit nennt 31 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents the design and implementation of a magnetic signal scanning and imaging system based on the giant magnetoimpedance (GMI) effect. The system employs a pair of performance-matched GMI sensing elements configured as a differential probe structure. Through co-optimized low-noise electronic and probe design, the system effectively suppresses both intrinsic sensor common-mode drift and external environmental magnetic noise, enabling high signal-to-noise ratio detection of nano-tesla to micro-tesla-level magnetic signals without magnetic shielding. Experimental results demonstrate that the differential system achieves significantly lower noise spectral density in the given unshielded environment compared to conventional GMI sensors (46 pT/Hz vs 286 pT/Hz at 1 Hz), with sensitivity of 186 790 V/T and spatial resolution better than 200 μm. Through scanning experiments on magnetic ink patterns in banknotes and on magnetic reference samples, as well as spatial resolution tests, the system’s excellent performance in weak magnetic field detection and spatial resolution was verified. Compared to superconducting quantum interference device scanning systems, which require liquid helium cooling, this system based on the GMI effect offers advantages of room-temperature operation, compact structure, and low cost. Relative to conventional single-element GMI microscopes, it achieves significant improvements in signal-to-noise ratio and environmental adaptability. This research provides a practical solution for high-resolution magnetic field imaging at room temperature, with broad application potential in materials magnetism, biomagnetic imaging, and nanomagnetic detection.

Autor:innen und Institutionen

  • Key Laboratory for Magnetism and Magnetic Functional Materials of the Ministry of Education, Lanzhou University, Lanzhou 730000, People's Republic of China.
  • Institute of Physics, Chinese Academy of Sciences, P.O. Box 603, Beijing 100190, People's Republic of China.

ORCID-Profile: Tao Yang, Zhoulu Yu, Xuekui Xi, Changjun Jiang, Guozhi Chai

Förderung

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China

Zitieren

APA

Yang, T., Yu, Z., Xi, X., Jiang, C., & Chai, G. (2026). Magnetic signal scan imaging system based on giant magnetoimpedance (GMI) differential sensor. Review of Scientific Instruments, 97(7). https://doi.org/10.1063/5.0313791

Vancouver

Yang T, Yu Z, Xi X, Jiang C, Chai G. Magnetic signal scan imaging system based on giant magnetoimpedance (GMI) differential sensor. Review of Scientific Instruments. 2026;97(7). doi:10.1063/5.0313791

BibTeX
@article{Yang2026,
  author = {Yang, Tao and Yu, Zhoulu and Xi, Xuekui and Jiang, Changjun and Chai, Guozhi},
  title = {Magnetic signal scan imaging system based on giant magnetoimpedance (GMI) differential sensor},
  journal = {Review of Scientific Instruments},
  year = {2026},
  volume = {97},
  number = {7},
  doi = {10.1063/5.0313791}
}
Kostenlos starten →