High density atomic oxygen microwave plasma source characterized by quantitative optical emission spectroscopy and two photon laser absorption induced fluorescence
Plasma Sources Science and Technology · 01.05.2026 · 35 (5) · 055008
DOI: 10.1088/1361-6595/ae63f3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Plasma Sources Science and Technology, online erschienen am 12.05.2026. Verfasst von I Stefanović und 5 weiteren Autor:innen. Die Arbeit nennt 48 Literaturangaben. Gefördert von: Ministry of Science, Innovation and Technological Development, Republic of Serbia, Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
The Miniature Microwave Inductively Coupled Plasma (MMWICP) device is investigated as a potential source of atomic oxygen (O) for various applications, including ultra-thin barrier film deposition. To the best of our knowledge, this is the first study combining two-photon absorption laser-induced fluorescence (TALIF) with quantitative optical emission spectroscopy (OES) to determine the atomic oxygen density in MW plasma. Due to its unique design, the MMWICP operates in a highly efficient H-mode, producing atomic oxygen densities of up to 7 × 10 −21 m −3 at a pressure of 150 Pa in pure oxygen. By adding 1% nitrogen to the gas mixture to enable OES measurements, the atomic oxygen density increases further, reaching up to 2 × 10 −22 m −3 . In addition to dissociative attachment, which is the main production mechanism of atomic oxygen, heavy-particle collisions between oxygen molecules and nitrogen metastable molecules in the N₂(A) state most likely contribute to the observed enhancement of the O density. Along the effluent, O losses are negligible under the applied plasma conditions. The gas temperature decreases rapidly from 1400 K in the plasma center to values between 400 K and 500 K at a distance of 30 mm. A similar value of approximately 500 K in the plasma effluent is obtained from Doppler broadening of the two- photon excitation profile of atomic oxygen. A comparison of the two independent diagnostics for the atomic oxygen density shows that both methods exhibit similar qualitative behavior with respect to variations in gas pressure. However, the absolute atomic oxygen densities obtained by TALIF are two to three times higher than those derived from OES, although the respective error bars overlap. The uncertainties associated with both methods are discussed, together with possible approaches to improve the quantitative agreement between the two techniques.
Förderung
- Ministry of Science, Innovation and Technological Development, Republic of Serbia
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Stefanović, I., Bibinov, N., Porteanu, H., Klute, M., Brinkmann, R., & Awakowicz, P. (2026). High density atomic oxygen microwave plasma source characterized by quantitative optical emission spectroscopy and two photon laser absorption induced fluorescence. Plasma Sources Science and Technology, 35(5), 055008. https://doi.org/10.1088/1361-6595/ae63f3
Vancouver
Stefanović I, Bibinov N, Porteanu H, Klute M, Brinkmann R, Awakowicz P. High density atomic oxygen microwave plasma source characterized by quantitative optical emission spectroscopy and two photon laser absorption induced fluorescence. Plasma Sources Science and Technology. 2026;35(5):055008. doi:10.1088/1361-6595/ae63f3
BibTeX
@article{Stefanovi2026,
author = {Stefanović, I and Bibinov, N and Porteanu, H-E and Klute, M and Brinkmann, R-P and Awakowicz, P},
title = {High density atomic oxygen microwave plasma source characterized by quantitative optical emission spectroscopy and two photon laser absorption induced fluorescence},
journal = {Plasma Sources Science and Technology},
year = {2026},
volume = {35},
number = {5},
pages = {055008},
doi = {10.1088/1361-6595/ae63f3}
}