Power law spectral photon-counting CT for quantitative effective atomic number and electron density imaging
Physics in Medicine & Biology · 28.07.2026 · 71 (14) · 145015
DOI: 10.1088/1361-6560/ae8aab ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 27.07.2026. Verfasst von Mohammed Alzaabi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Khalifa University, Abu Dhabi, United Arab Emirates. Hauptthemen laut MEDLINE: Photons, Tomography, X-Ray Computed, Electrons. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Khalifa University of Science and Technology, Abu Dhabi, United Arab Emirates.
Abstract (Originalsprache)
Objective. To develop and evaluate a scanner-specific power law method for voxelwise effective atomic number ( Z eff ) and electron density ( ρ e ) imaging on a commercial spectral photon-counting CT (SPCCT) system, and to demonstrate its applicability to tissue characterization in heterogeneous samples. Approach. The x-ray linear attenuation coefficient μ ( E ) was modeled as a power law sum of photoelectric, Compton and empirical correction terms. Model coefficients were fitted to NIST cross sections for Z = 6 –21 over the scanner energy range from 7 to 115 keV. A QRM spectral-computed tomography (CT) phantom containing soft-tissue-equivalent, hydroxyapatite and iodine inserts was scanned on a MARS Microlab 5 × 120 SPCCT system in five detector energy bins. For each bin, reconstructed SPCCT μ images were linearly calibrated to NIST μ , and the calibrated μ ( E ) served as input to four-window and dual-energy models to estimate voxelwise Z eff and ρ e . The same calibration and model were applied, without retuning, to a meat sample with embedded iodine vials. Main results. Using NIST μ as input, the four-window formalism gave mean absolute errors of approximately 1% for both Z eff and ρ e . On calibrated SPCCT images, errors were 4.9% and 2.1% for Z eff and ρ e with the four-window model, and 3.6% and 1.7% with the best dual-energy pair (50–60 / 60–79 keV). The same framework, applied without retuning, separated fat, muscle, bone and iodine in the heterogeneous meat sample. Significance. A scanner-specific power law model of μ ( E ) combined with bin-wise linear calibration can deliver accurate Z eff and ρ e from a single SPCCT acquisition. Optimized dual-energy windows achieve near-percent ρ e accuracy for clinically relevant materials, providing a quantitative basis for tissue characterization with photon-counting CT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Khalifa University, Abu Dhabi, United Arab Emirates.
- Ferhat Abbes University, Setif, Algeria.
ORCID-Profile: Mohammed Alzaabi, Abderaouf Behouch, Briya Tariq, Nabil Maalej
Förderung
- Khalifa University of Science and Technology, Abu Dhabi, United Arab Emirates
Zitieren
APA
Alzaabi, M., Behouch, A., Tariq, B., Raja, A., & Maalej, N. (2026). Power law spectral photon-counting CT for quantitative effective atomic number and electron density imaging. Physics in Medicine & Biology, 71(14), 145015. https://doi.org/10.1088/1361-6560/ae8aab
Vancouver
Alzaabi M, Behouch A, Tariq B, Raja A, Maalej N. Power law spectral photon-counting CT for quantitative effective atomic number and electron density imaging. Physics in Medicine & Biology. 2026;71(14):145015. doi:10.1088/1361-6560/ae8aab
BibTeX
@article{Alzaabi2026,
author = {Alzaabi, Mohammed and Behouch, Abderaouf and Tariq, Briya and Raja, Aamir and Maalej, Nabil},
title = {Power law spectral photon-counting CT for quantitative effective atomic number and electron density imaging},
journal = {Physics in Medicine & Biology},
year = {2026},
volume = {71},
number = {14},
pages = {145015},
doi = {10.1088/1361-6560/ae8aab}
}
EUVIMED