EUVIMEDEUVIMED entdecken
Crossref

Feasibility study of non-invasive blood pressure measurement based on multidimensional characteristics of radial artery pressure pulse wave

Ruijie Li iD, Yuetang Li iD, Hui Li iD, Zehua Ma iD, Zhidong Zhang iD, Zhenhua Li iD, Jiuzhang Men iD, Chenyang Xue iD

Physiological Measurement · 29.05.2026 · 47 (5) · 055022

DOI: 10.1088/1361-6579/ae7010 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physiological Measurement, online erschienen am 29.05.2026. Verfasst von Ruijie Li und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Instrumentation and Electronics, North University of China, Taiyuan, People's Republic of China. Hauptthemen laut MEDLINE: Radial Artery, Pulse Wave Analysis, Blood Pressure Determination, Blood Pressure. Die Arbeit nennt 41 Literaturangaben. Gefördert von: Key Research and Development Program of Hainan Province, Research on Digital Enabling Innovation and Development of Traditional Chinese Medicine Industry in Shanxi Province, Key Research and Development Program of Shanxi Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective. This study focuses on a non-invasive blood pressure prediction method based on radial artery pressure pulse wave feature analysis, aiming to achieve rapid and accurate blood pressure measurement, help doctors diagnose diseases more accurately, promote the development of digital pulse diagnosis, and provide a new approach for blood pressure monitoring in wearable devices. Approach. By extracting 25 multidimensional features (including time-domain, frequency-domain, and nonlinear features) of the radial artery pressure pulse wave, and after feature correlation analysis and importance assessment, weights were assigned to establish a blood pressure prediction model based on the random forest algorithm. Main results. Experimental results show that the mean absolute errors of systolic and diastolic blood pressure prediction are 3.39 mmHg and 2.06 mmHg, respectively, with standard deviations of 4.76 mmHg and 2.78 mmHg, respectively, both meeting the commonly referenced AAMI performance criteria ( M A E ⩽ 5 mmHg and S T D ⩽ 84 mmHg), which are widely used as benchmarking thresholds in non-invasive blood pressure estimation studies. Significance. Compared with current mainstream methods, such as Photoplethysmography combined with Electrocardiogram (ECG) prediction and pulse wave velocity estimation, this model demonstrates higher prediction accuracy and convenience advantages in wearable device applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radial ArteryPulse Wave AnalysisBlood Pressure DeterminationBlood PressureHumansFeasibility StudiesSignal Processing, Computer-AssistedMale

Stichwörter der Autor:innen

correlation analysismachine learningnon-invasive blood pressure monitoringradial artery pressure pulse wave characteristics

Autor:innen und Institutionen

  • School of Instrumentation and Electronics, North University of China, Taiyuan, People's Republic of China.
  • School of Economics and Management, North University of China, Taiyuan, People's Republic of China.
  • College of Basic Medical Science, Shanxi University of Chinese Medicine, Jinzhong, People's Republic of China.

ORCID-Profile: Ruijie Li, Yuetang Li, Hui Li, Zehua Ma, Zhidong Zhang, Zhenhua Li, Jiuzhang Men, Chenyang Xue

Förderung

  • Key Research and Development Program of Hainan Province
  • Research on Digital Enabling Innovation and Development of Traditional Chinese Medicine Industry in Shanxi Province
  • Key Research and Development Program of Shanxi Province

Zitieren

APA

Li, R., Li, Y., Li, H., Ma, Z., Zhang, Z., Li, Z., Men, J., & Xue, C. (2026). Feasibility study of non-invasive blood pressure measurement based on multidimensional characteristics of radial artery pressure pulse wave. Physiological Measurement, 47(5), 055022. https://doi.org/10.1088/1361-6579/ae7010

Vancouver

Li R, Li Y, Li H, Ma Z, Zhang Z, Li Z, et al. Feasibility study of non-invasive blood pressure measurement based on multidimensional characteristics of radial artery pressure pulse wave. Physiological Measurement. 2026;47(5):055022. doi:10.1088/1361-6579/ae7010

BibTeX
@article{Li2026,
  author = {Li, Ruijie and Li, Yuetang and Li, Hui and Ma, Zehua and Zhang, Zhidong and Li, Zhenhua and Men, Jiuzhang and Xue, Chenyang},
  title = {Feasibility study of non-invasive blood pressure measurement based on multidimensional characteristics of radial artery pressure pulse wave},
  journal = {Physiological Measurement},
  year = {2026},
  volume = {47},
  number = {5},
  pages = {055022},
  doi = {10.1088/1361-6579/ae7010}
}
Kostenlos starten →