Continuous blood pressure monitoring via hemodynamic parameter and pulse transit time derived from capacitive sensing pads
Physiological Measurement · 30.04.2026 · 47 (4) · 045006
DOI: 10.1088/1361-6579/ae575a ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiological Measurement, online erschienen am 08.04.2026. Verfasst von Yu-Jen Cheng und 4 weiteren Autor:innen. Beteiligte Einrichtung: Mechanical Engineering Department, University of Washington, Seattle, WA 98195, United States of America. Hauptthemen laut MEDLINE: Pulse Wave Analysis, Electric Capacitance, Hemodynamics, Blood Pressure Determination. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NHLBI NIH HHS, NIA NIH HHS, National Heart, Lung, and Blood Institute.
Abstract (Originalsprache)
Objective. Continuous blood pressure (BP) monitoring is crucial for detecting nocturnal hypertension and acute hemodynamic changes. Conventional cuff-based methods disrupt sleep and miss transient BP fluctuations from sleep-related events or instability. Cuffless methods, such as pulse transit time (PTT), offer potential but often struggle to reliably track acute BP fluctuations due to complex and nonlinear hemodynamics. Approach. We developed a capacitive sensing pad system incorporating PTT with additional hemodynamic features for unobtrusive, continuous BP monitoring in supine subjects. The pad contains ultra-sensitive single-electrode capacitive (SEC) sensors made from carbon nanotube composites. In passive contact, SEC sensor on the back of the chest captures intrathoracic blood volume changes through deep tissue permittivity and ballistocardiography, while another under the leg detects arterial pulse-induced tissue vibrations. PTT is derived from the temporal delay between chest and leg signals. A neural network model incorporates PTT and intrathoracic blood volume features to improve BP estimation. Main results. In human trials ( N = 30) with arm-cuff reference, the system showed strong correlation ( r ⩾ 0.94), with a mean error (ME) ⩽ 0.1 mmHg and standard deviation (SD) ⩽ 5.6 mmHg. In a subset ( N = 8) with continuous finger-cuff reference, it maintained strong correlation ( r ⩾ 0.89), with a ME ⩽ 0.2 mmHg and SD ⩽ 7.8 mmHg. Significance. These results suggest the possibility of bed-based unobtrusive and continuous BP monitoring in the supine position.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Mechanical Engineering Department, University of Washington, Seattle, WA 98195, United States of America.
- Division of Cardiology, University of Washington, Seattle, WA 98195, United States of America.
- Mechanical Engineering Department, University of Maryland, College Park, MD 20742, United States of America.
ORCID-Profile: Yu-Jen Cheng, Edward Kim, Jin-Oh Hahn, Jae-Hyun Chung, Younghoon Kwon
Förderung
- NHLBI NIH HHS
- NIA NIH HHS
- National Heart, Lung, and Blood Institute
Zitieren
APA
Cheng, Y. J., Kim, E., Hahn, J. O., Chung, J. H., & Kwon, Y. (2026). Continuous blood pressure monitoring via hemodynamic parameter and pulse transit time derived from capacitive sensing pads. Physiological Measurement, 47(4), 045006. https://doi.org/10.1088/1361-6579/ae575a
Vancouver
Cheng YJ, Kim E, Hahn JO, Chung JH, Kwon Y. Continuous blood pressure monitoring via hemodynamic parameter and pulse transit time derived from capacitive sensing pads. Physiological Measurement. 2026;47(4):045006. doi:10.1088/1361-6579/ae575a
BibTeX
@article{Cheng2026,
author = {Cheng, Yu-Jen and Kim, Edward and Hahn, Jin-Oh and Chung, Jae-Hyun and Kwon, Younghoon},
title = {Continuous blood pressure monitoring via hemodynamic parameter and pulse transit time derived from capacitive sensing pads},
journal = {Physiological Measurement},
year = {2026},
volume = {47},
number = {4},
pages = {045006},
doi = {10.1088/1361-6579/ae575a}
}
EUVIMED