Towards fair and trustworthy heart rate estimation from wrist-worn photoplethysmography: a multi-wavelength dataset and uncertainty-aware deep learning approach evaluated across skin tones, sexes, and motion conditions
Physiological Measurement · 30.04.2026 · 47 (4) · 045004
DOI: 10.1088/1361-6579/ae56ae ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiological Measurement, online erschienen am 08.04.2026. Verfasst von Daniel Ray und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering, Manchester Metropolitan University, Manchester, United Kingdom. Hauptthemen laut MEDLINE: Photoplethysmography, Deep Learning, Wrist, Heart Rate. Die Arbeit nennt 74 Literaturangaben.
Abstract (Originalsprache)
Objective. To improve fairness (reduced disparities across skin tones and sexes) and trust (well-calibrated uncertainty metrics that indicate unreliable predictions) in wrist-worn photoplethysmography (PPG) heart rate estimation. While PPG offers a convenient, low-cost method for continuous heart rate monitoring, accuracy is often degraded by motion artefacts and demographic variation. Approach. We collected a multi-wavelength (blue, green, red, IR) wrist-worn PPG dataset covering diverse activities, skin tones, and sexes, and developed a multi-branch PPG-accelerometer fusion convolutional neural network quantifying both aleatoric and epistemic uncertainty (the latter via Monte Carlo dropout, concrete dropout, and deep ensembles). We compared wavelength sets, quantified demographic effects, and applied uncertainty-aware post-processing to filter out high-uncertainty predictions. Evaluation used leave-one-subject-out cross validation across both the collected multi-wavelength dataset and five commonly used single-wavelength datasets. Main results. Multi-wavelength fusion improved accuracy under motion, with blue-green-red-IR achieving the lowest mean absolute error (MAE). Baseline error was higher for participants with darker skin tones and for females; uncertainty-guided rejection reduced MAE and effectively eliminated these gaps (reducing parity gaps from 1.2 BPM to 0.0 BPM for skin tone). Concrete dropout provided the best calibration-accuracy-efficiency trade-off, achieving the lowest average miscalibration area (MA = 0.12 ) while maintaining competitive MAE. Significance. Combining calibrated uncertainty with group-aware evaluation yields a more fair and trustworthy wrist-worn PPG heart rate estimation pipeline, supporting responsible deployment in consumer and sports contexts and informing bias-aware clinical development.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Engineering, Manchester Metropolitan University, Manchester, United Kingdom.
ORCID-Profile: Daniel Ray, Tim Collins, Prasad V S Ponnapalli
Zitieren
APA
Ray, D., Collins, T., & Ponnapalli, P. V. S. (2026). Towards fair and trustworthy heart rate estimation from wrist-worn photoplethysmography: a multi-wavelength dataset and uncertainty-aware deep learning approach evaluated across skin tones, sexes, and motion conditions. Physiological Measurement, 47(4), 045004. https://doi.org/10.1088/1361-6579/ae56ae
Vancouver
Ray D, Collins T, Ponnapalli PVS. Towards fair and trustworthy heart rate estimation from wrist-worn photoplethysmography: a multi-wavelength dataset and uncertainty-aware deep learning approach evaluated across skin tones, sexes, and motion conditions. Physiological Measurement. 2026;47(4):045004. doi:10.1088/1361-6579/ae56ae
BibTeX
@article{Ray2026,
author = {Ray, Daniel and Collins, Tim and Ponnapalli, Prasad V S},
title = {Towards fair and trustworthy heart rate estimation from wrist-worn photoplethysmography: a multi-wavelength dataset and uncertainty-aware deep learning approach evaluated across skin tones, sexes, and motion conditions},
journal = {Physiological Measurement},
year = {2026},
volume = {47},
number = {4},
pages = {045004},
doi = {10.1088/1361-6579/ae56ae}
}
EUVIMED