EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Non-invasive hemodynamic monitoring during hemorrhage and blood transfusion: opportunities and challenges

Parham Rezaei iD, Sina Masoumi Shahrbabak iD, John Vandenberge, Yuanyuan Zhou iD, Demet Tangolar iD, Nancy Kim, Douglas Tran, Randy Perez iD, Donghyeon Kim, Nicholas Burch iD, Zeineb Bouzid, Rayan Bahrami und 5 weitere

Physiological Measurement · 30.04.2026 · 47 (4) · 045003

DOI: 10.1088/1361-6579/ae5441 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physiological Measurement, online erschienen am 08.04.2026. Verfasst von Parham Rezaei und 16 weiteren Autor:innen. Beteiligte Einrichtung: Mechanical Engineering, University of Maryland, College Park, MD 20742, United States of America. Hauptthemen laut MEDLINE: Blood Transfusion, Hemorrhage, Hemodynamic Monitoring, Hemodynamics. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: U.S. Office of Naval Research, Office of Naval Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective . We investigated (i) if blood volume decompensation status (BVDS) can be trend-tracked by hemodynamic parameters, and (ii) if hemodynamic parameters capable of trend-tracking BVDS can be trend-tracked by the physio-markers derived from the physiological signals measured using wearable sensors. Approach . In 9 pigs undergoing controlled hemorrhage and blood transfusion, we measured gold standard arterial blood pressure (BP), heart rate (HR), stroke volume (SV), and cardiac output (CO) via invasive aortic BP and flow signals. In addition, we derived non-invasive physio-markers from the electrocardiogram, photoplethysmogram (PPG), and seismocardiogram signals measured using wearable sensors. Then, we determined the best hemodynamic parameters to trend-track BVDS by comparing their correlation with BVDS. Finally, we investigated the feasibility of trend-tracking BVDS via non-invasive physio-markers in terms of their correlation with hemodynamic parameters as well as BVDS. Main results . SV and CO could trend-track BVDS more consistently and explainably than BP and HR during hemorrhage and blood transfusion. The physio-markers of SV (the ratio between left ventricular ejection time (LVET) and pre-ejection period (PEP): LVET/PEP and PPG amplitude: A PPG ) and CO (HR·LVET/PEP and HR· A PPG ) showed close and monotonic relationships to SV (LVET/PEP: Spearman correlation 0.96 (0.93–0.98) and Pearson correlation 0.96 (0.93–0.98)) and CO (HR·LVET/PEP: Spearman correlation 0.95 (0.91–0.97) and Pearson correlation 0.91 (0.89–0.97)), and they likewise showed close and monotonic relationships to BVDS. However, substantial inter-individual variability in the hemodynamic parameters and their physio-markers was also observed. Significance . These findings suggest the feasibility of wearable-enabled hemodynamic monitoring during hemorrhage and blood transfusion, as well as the challenges therein.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood TransfusionHemorrhageHemodynamic MonitoringHemodynamicsAnimalsSwineHeart RateStroke VolumeBlood PressureWearable Electronic Devices

Stichwörter der Autor:innen

blood transfusionelectrocardiogram (ECG)hemodynamic monitoringhemorrhagephotoplethysmogram (PPG)seismocardiogram (SCG)

Autor:innen und Institutionen

  • Mechanical Engineering, University of Maryland, College Park, MD 20742, United States of America.
  • Surgery, University of Maryland, Baltimore, MD 21201, United States of America.
  • Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States of America.
  • Biomedical and Electrical Engineering, University of Portland, Portland, OR 97203, United States of America.
  • Mechanical Engineering, Chonnam National University, Gwangju, Republic of Korea.

ORCID-Profile: Parham Rezaei, Sina Masoumi Shahrbabak, Yuanyuan Zhou, Demet Tangolar, Randy Perez, Nicholas Burch, Jacob P Kimball, Chang-Sei Kim, Jin-Oh Hahn

Förderung

  • U.S. Office of Naval Research
  • Office of Naval Research

Zitieren

APA

Rezaei, P., Masoumi Shahrbabak, S., Vandenberge, J., Zhou, Y., Tangolar, D., Kim, N., Tran, D., Perez, R., Kim, D., Burch, N., Bouzid, Z., Bahrami, R., Kimball, J. P., Kim, C. S., Wu, Z. J., Inan, O. T., & Hahn, J. O. (2026). Non-invasive hemodynamic monitoring during hemorrhage and blood transfusion: opportunities and challenges. Physiological Measurement, 47(4), 045003. https://doi.org/10.1088/1361-6579/ae5441

Vancouver

Rezaei P, Masoumi Shahrbabak S, Vandenberge J, Zhou Y, Tangolar D, Kim N, et al. Non-invasive hemodynamic monitoring during hemorrhage and blood transfusion: opportunities and challenges. Physiological Measurement. 2026;47(4):045003. doi:10.1088/1361-6579/ae5441

BibTeX
@article{Rezaei2026,
  author = {Rezaei, Parham and Masoumi Shahrbabak, Sina and Vandenberge, John and Zhou, Yuanyuan and Tangolar, Demet and Kim, Nancy and Tran, Douglas and Perez, Randy and Kim, Donghyeon and Burch, Nicholas and Bouzid, Zeineb and Bahrami, Rayan and Kimball, Jacob P and Kim, Chang-Sei and Wu, Zhongjun J and Inan, Omer T and Hahn, Jin-Oh},
  title = {Non-invasive hemodynamic monitoring during hemorrhage and blood transfusion: opportunities and challenges},
  journal = {Physiological Measurement},
  year = {2026},
  volume = {47},
  number = {4},
  pages = {045003},
  doi = {10.1088/1361-6579/ae5441}
}
Kostenlos starten →