Time-of-flight abdominal wall displacement for non-invasive longitudinal monitoring of pulmonary function
Physiological Measurement · 2026
DOI: 10.1088/1361-6579/ae484a ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiological Measurement, 2026. Verfasst von Wesam Bachir. Beteiligte Einrichtung: Institute of Metrology and Biomedical Engineering, Faculty of Mechatronics, Warsaw University of Technology, 02-525 Warsaw, Poland. Hauptthemen laut MEDLINE: Respiratory Function Tests, Abdominal Wall, Lung. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Biomdedical Engineering Discipline.
Abstract (Originalsprache)
Objective . Spirometry is the clinical gold standard for pulmonary function testing, but its reliance on mouthpiece-based airflow, trained supervision, and patient effort limits its use for frequent or home-based monitoring. This study investigates a single-point time-of-flight (TOF) sensor to capture abdominal wall displacement as a non-contact surrogate for spirometric indices. Approach . Displacement signals were recorded from 31 adult volunteers during quiet breathing, vital capacity (VC), and forced VC (FVC) manoeuvres, with simultaneous spirometry as reference. A preprocessing framework with filtering, segmentation, and feature extraction was developed, and subject-specific two-point calibration mapped displacement to lung volume. TOF-derived measures were compared to spirometry using agreement analyses, with BA plots used to quantify bias and limits of agreement for key indices. Main results . TOF signals accurately reproduced volume-related parameters: tidal volume, VC, and maximal voluntary ventilation agreed well with spirometry after calibration, with mean differences within clinically acceptable ranges. Estimation of the FEV₁/FVC ratio showed greater variability. After exclusion of one artifactual TOF measurement, BA analysis showed a small positive bias (∼+0.05) with limits of agreement of approximately −0.1 to +0.2. All TOF-derived ratios exceeded the clinical threshold of 0.7, supporting correct classification of normal ventilatory function in this cohort. Significance . These results indicate that although single-point TOF sensing cannot replace spirometry, it offers a non-contact, subject-specific calibration-minimal method for estimating pulmonary function, with promising applications in longitudinal monitoring, telehealth, and early screening.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Metrology and Biomedical Engineering, Faculty of Mechatronics, Warsaw University of Technology, 02-525 Warsaw, Poland.
ORCID-Profile: Wesam Bachir
Förderung
- Biomdedical Engineering Discipline
Zitieren
APA
Bachir, W. (2026). Time-of-flight abdominal wall displacement for non-invasive longitudinal monitoring of pulmonary function. Physiological Measurement. https://doi.org/10.1088/1361-6579/ae484a
Vancouver
Bachir W. Time-of-flight abdominal wall displacement for non-invasive longitudinal monitoring of pulmonary function. Physiological Measurement. 2026. doi:10.1088/1361-6579/ae484a
BibTeX
@article{Bachir2026,
author = {Bachir, Wesam},
title = {Time-of-flight abdominal wall displacement for non-invasive longitudinal monitoring of pulmonary function},
journal = {Physiological Measurement},
year = {2026},
doi = {10.1088/1361-6579/ae484a}
}