Reduction of motion artifacts from photoplethysmography signals using learned convolutional sparse coding
Physiological Measurement · 2026
DOI: 10.1088/1361-6579/ae35cb ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiological Measurement, 2026. Verfasst von Giulio Basso und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands. Hauptthemen laut MEDLINE: Photoplethysmography, Artifacts, Signal Processing, Computer-Assisted, Deep Learning. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: ITEA, Eindhoven MedTech Innovation Center.
Abstract (Originalsprache)
Objective. Wearable devices with embedded photoplethysmography (PPG) enable continuous non-invasive monitoring of cardiac activity, offering a promising strategy to reduce the global burden of cardiovascular diseases. However, monitoring during daily life introduces motion artifacts that can compromise the signals. Traditional signal decomposition techniques often fail with severe artifacts. Deep learning denoisers are more effective but have poorer interpretability, which is critical for clinical acceptance. This study proposes a framework that combines the advantages of both signal decomposition and deep learning approaches. Approach. We leverage algorithm unfolding to integrate prior knowledge about the PPG structure into a deep neural network, improving its interpretability. A learned convolutional sparse coding model encodes the signal into a sparse representation using a learned dictionary of kernels that capture recurrent morphological patterns. The network is trained for denoising using the PulseDB dataset and a synthetic motion artifact model from the literature. Performance is benchmarked with PPG during daily activities using the PPG-DaLiA dataset and compared with two reference deep learning methods. Main results. On the synthetic dataset, the proposed method, on average, improved the signal-to-noise ratio (SNR) from −7.06 dB to 11.23 dB and reduced the heart rate mean absolute error (MAE) by 55%. On the PPG-DaLiA dataset, the MAE decreased by 23%. The proposed method obtained higher SNR and comparable MAE to the reference methods. Significance. Our method effectively enhances the quality of PPG signals from wearable devices and enables the extraction of meaningful waveform features, which may inspire innovative tools for monitoring cardiovascular diseases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
- Eindhoven MedTech Innovation Center (e/MTIC), Eindhoven, The Netherlands.
- Philips, Eindhoven, The Netherlands.
ORCID-Profile: Giulio Basso, Xi Long, Reinder Haakma, Rik Vullings
Förderung
- ITEA
- Eindhoven MedTech Innovation Center
Zitieren
APA
Basso, G., Long, X., Haakma, R., & Vullings, R. (2026). Reduction of motion artifacts from photoplethysmography signals using learned convolutional sparse coding. Physiological Measurement. https://doi.org/10.1088/1361-6579/ae35cb
Vancouver
Basso G, Long X, Haakma R, Vullings R. Reduction of motion artifacts from photoplethysmography signals using learned convolutional sparse coding. Physiological Measurement. 2026. doi:10.1088/1361-6579/ae35cb
BibTeX
@article{Basso2026,
author = {Basso, Giulio and Long, Xi and Haakma, Reinder and Vullings, Rik},
title = {Reduction of motion artifacts from photoplethysmography signals using learned convolutional sparse coding},
journal = {Physiological Measurement},
year = {2026},
doi = {10.1088/1361-6579/ae35cb}
}
EUVIMED