EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Catheter-to-tissue contact angle’s effect on lesion formation and characterisation using multichannel bioimpedance method

Anh Huyen Ngo iD, Minh Thao Hoang iD, Phuong Linh Nguyen iD, Thu Van Nguyen, Duc Thuan Nguyen, Minh Duc Nguyen iD

Physiological Measurement · 2025

DOI: 10.1088/1361-6579/add07f ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physiological Measurement, 2025. Verfasst von Anh Huyen Ngo und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical and Electronic Engineering, Hanoi University of Science and Technology, Hanoi, Vietnam. Hauptthemen laut MEDLINE: Electric Impedance, Catheters, Catheter Ablation. Die Arbeit nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Vietnam National Foundation for Science and Technology Development.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective. Radiofrequency (RF) catheter ablation is a standard treatment for patients with cardiac arrhythmias, providing an efficient, minimally invasive solution. However, the ablation efficiency remains suboptimal due to numerous contributed factors that are overlooked in the literature and not monitored during the procedure. This paper explores the effect of catheter-to-tissue contact angles on lesion formations and the feasibility of the multichannel bioimpedance method in characterising the angles to inform cardiologists. Approach. Two silico simulations based on a realistic human model were built to: (1) simulate lesion formations with different catheter-to-tissue angles under varying conditions of powers and convection cooling, and (2) simulate multichannel bioimpedances measured at each catheter’s location and angle. 13 locations were picked in all four chambers with 3 contact conditions (catheter lies along the muscle (0° and 180°), in perpendicular to the muscle (90°) and in middle angles (45° and 135°)). 64 electrodes divided into 4 bands were placed on the thorax for multichannel bioimpedances (3-terminal) measured between the catheter’s second electrode E2 ( I +, V +), and each pair of adjacent surface electrodes ( I − , V − ). ANOVA and Tukey’s Honestly Significant Difference (HSD) tests were used to evaluate the contact angle’s effect on the lesion formations and the bioimpedance’s capability in distinguishing between angles. Main results. The results showed that 0° and 180° configurations generated significantly different lesions from other angles. The multichannel bioimpedances could recognise 0°/180° from other angles and correlated moderately to lesion sizes at low ablation power. Significance. This paper concludes that catheter-to-tissue angles can influence the lesion outcomes significantly and the multichannel bioimpedance is able to detect the angles that matter.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electric ImpedanceCathetersCatheter AblationHumansElectrodesComputer Simulation

Stichwörter der Autor:innen

bio-impedancecardiac ablationcatheter-to-tissue contact

Autor:innen und Institutionen

  • School of Electrical and Electronic Engineering, Hanoi University of Science and Technology, Hanoi, Vietnam.
  • School of Biomedical Engineering, University of Sydney, Sydney, Australia.
  • International University-Vietnam National University, Hanoi, Vietnam.
  • Westmead Applied Research Centre, University of Sydney, Sydney, Australia.

ORCID-Profile: Anh Huyen Ngo, Minh Thao Hoang, Phuong Linh Nguyen, Minh Duc Nguyen

Förderung

  • Vietnam National Foundation for Science and Technology Development

Zitieren

APA

Ngo, A. H., Hoang, M. T., Nguyen, P. L., Nguyen, T. V., Nguyen, D. T., & Nguyen, M. D. (2025). Catheter-to-tissue contact angle’s effect on lesion formation and characterisation using multichannel bioimpedance method. Physiological Measurement. https://doi.org/10.1088/1361-6579/add07f

Vancouver

Ngo AH, Hoang MT, Nguyen PL, Nguyen TV, Nguyen DT, Nguyen MD. Catheter-to-tissue contact angle’s effect on lesion formation and characterisation using multichannel bioimpedance method. Physiological Measurement. 2025. doi:10.1088/1361-6579/add07f

BibTeX
@article{Ngo2025,
  author = {Ngo, Anh Huyen and Hoang, Minh Thao and Nguyen, Phuong Linh and Nguyen, Thu Van and Nguyen, Duc Thuan and Nguyen, Minh Duc},
  title = {Catheter-to-tissue contact angle’s effect on lesion formation and characterisation using multichannel bioimpedance method},
  journal = {Physiological Measurement},
  year = {2025},
  doi = {10.1088/1361-6579/add07f}
}
Kostenlos starten →