Bed sensor ballistocardiogram for non-invasive detection of atrial fibrillation: a comprehensive clinical study
Physiological Measurement · 2025
DOI: 10.1088/1361-6579/adbb52 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiological Measurement, 2025. Verfasst von Jonas Sandelin und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Computing, Digital Health Technology Group, University of Turku, Vesilinnantie 3, 20500 Turku, Finland. Hauptthemen laut MEDLINE: Atrial Fibrillation, Ballistocardiography. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Business Finland, Electronic Components and Systems for European Leadership.
Abstract (Originalsprache)
Objective
Atrial fibrillation (AFib) is a common cardiac arrhythmia associated with high morbidity and mortality, making early detection and continuous monitoring essential to prevent complications like stroke. This study explores the potential of using a ballistocardiogram (BCG) based bed sensor for the detection of AFib. Approach. We conducted a comprehensive clinical study with night hospital recordings from 116 patients, divided into 72 training and 44 test subjects. The study employs established methods such as autocorrelation to identify AFib from BCG signals. Spot and continuous Holter ECG were used as reference methods for AFib detection against which BCG rhythm classifications were compared.
Results
Our findings demonstrate the potential of BCG-based AFib detection, achieving 94% accuracy on the training set using a rule-based method. Furthermore, the machine learning model trained with the training set achieved an AUROC score of 97% on the test set. Significance. This innovative approach shows promise for accurate, non-invasive, and continuous monitoring of AFib, contributing to improved patient care and outcomes, particularly in the context of home-based or hospital settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Computing, Digital Health Technology Group, University of Turku, Vesilinnantie 3, 20500 Turku, Finland.
- Heart Center, Turku University Hospital and University of Turku, Vesilinnantie 3, 20500 Turku, Finland.
ORCID-Profile: Jonas Sandelin, O Lahdenoja, I Elnaggar, R Rekola, A Anzanpour, S Seifizarei, M Kaisti, T Koivisto, J Lehto, J Nuotio, J Jaakkola, A Relander, J Airaksinen, T Kiviniemi
Förderung
- Business Finland
- Electronic Components and Systems for European Leadership
Zitieren
APA
Sandelin, J., Lahdenoja, O., Elnaggar, I., Rekola, R., Anzanpour, A., Seifizarei, S., Kaisti, M., Koivisto, T., Lehto, J., Nuotio, J., Jaakkola, J., Relander, A., Vasankari, T., Airaksinen, J., & Kiviniemi, T. (2025). Bed sensor ballistocardiogram for non-invasive detection of atrial fibrillation: a comprehensive clinical study. Physiological Measurement. https://doi.org/10.1088/1361-6579/adbb52
Vancouver
Sandelin J, Lahdenoja O, Elnaggar I, Rekola R, Anzanpour A, Seifizarei S, et al. Bed sensor ballistocardiogram for non-invasive detection of atrial fibrillation: a comprehensive clinical study. Physiological Measurement. 2025. doi:10.1088/1361-6579/adbb52
BibTeX
@article{Sandelin2025,
author = {Sandelin, Jonas and Lahdenoja, O and Elnaggar, I and Rekola, R and Anzanpour, A and Seifizarei, S and Kaisti, M and Koivisto, T and Lehto, J and Nuotio, J and Jaakkola, J and Relander, A and Vasankari, T and Airaksinen, J and Kiviniemi, T},
title = {Bed sensor ballistocardiogram for non-invasive detection of atrial fibrillation: a comprehensive clinical study},
journal = {Physiological Measurement},
year = {2025},
doi = {10.1088/1361-6579/adbb52}
}