EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Detection of Spatio‐Temporal Dispersion Electrograms Using Complex Signal Identification‐Labeled Abnormal Potential Areas in Patients With Persistent Atrial Fibrillation

Kazuki Ito, Yoshihisa Naruse iD, Yuki Tokonami, Yutaro Kaneko iD, Makoto Sano, Yuichiro Maekawa iD

Journal of Cardiovascular Electrophysiology · 2026

DOI: 10.1111/jce.70400 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2026. Verfasst von Kazuki Ito und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine III, Division of Cardiology, Hamamatsu University School of Medicine, Handayama, Chuo-ku, Hamamatsu, Japan. Hauptthemen laut MEDLINE: Atrial Fibrillation, Electrophysiologic Techniques, Cardiac, Action Potentials, Signal Processing, Computer-Assisted. Die Arbeit nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Ablation targeting spatio‐temporal dispersion electrograms (STDEs) in addition to pulmonary vein isolation (PVI) has been reported to reduce atrial fibrillation (AF) recurrence in patients with persistent AF.

Background

However, STDE identification remains subjective. Complex Signal Identification (CSI), integrated into the CARTO 3 mapping system, automatically quantifies electrogram characteristics. We evaluated whether CSI parameters can accurately identify STDEs.

Methods

We retrospectively analyzed intracardiac electrogram points from five consecutive patients who underwent catheter ablation for persistent AF using the CARTO 3 version 8 mapping system (Biosense Webster, Diamond Bar, CA, USA) between October and December 2024 to evaluate the ability of CSI parameters to identify STDEs. STDEs were identified and marked by the operator using an OCTARAY catheter.

Results

A total of 4453 electrogram points obtained before ablation were analyzed. Among all CSI metrics, the fractionation score demonstrated the highest diagnostic accuracy. An optimal cutoff of 4.1 yielded an area under the curve (AUC) of 0.905 (95% CI: 0.892–0.918), with a sensitivity of 80.4%, specificity of 98.6%, positive predictive value of 94.1%, and negative predictive value of 93.1%. In contrast, complex duration (cutoff ≥ 50 ms), %cycle length (cutoff ≥ 15%), and complex onset (cutoff ≤ −32) showed AUCs of 0.613 (95% CI: 0.557–0.668), 0.599 (95% CI: 0.538–0.660), and 0.525 (95% CI: 0.461–0.589), respectively.

Conclusion

A CSI fractionation score cutoff of 4.1 identified STDEs with high accuracy, suggesting that CSI‐guided mapping may serve as a practical tool for adjunctive ablation beyond PVI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationElectrophysiologic Techniques, CardiacAction PotentialsSignal Processing, Computer-AssistedHeart RateHumansRetrospective StudiesPredictive Value of TestsCatheter AblationTime FactorsFemaleMaleMiddle AgedAgedTreatment OutcomeReproducibility of Results

Stichwörter der Autor:innen

CARTO 3 version 8complex signal identificationpersistent atrial fibrillationspatio‐temporal dispersion electrograms

Autor:innen und Institutionen

  • Department of Internal Medicine III, Division of Cardiology, Hamamatsu University School of Medicine, Handayama, Chuo-ku, Hamamatsu, Japan.

ORCID-Profile: Yoshihisa Naruse, Yutaro Kaneko, Yuichiro Maekawa

Zitieren

APA

Ito, K., Naruse, Y., Tokonami, Y., Kaneko, Y., Sano, M., & Maekawa, Y. (2026). Detection of Spatio‐Temporal Dispersion Electrograms Using Complex Signal Identification‐Labeled Abnormal Potential Areas in Patients With Persistent Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70400

Vancouver

Ito K, Naruse Y, Tokonami Y, Kaneko Y, Sano M, Maekawa Y. Detection of Spatio‐Temporal Dispersion Electrograms Using Complex Signal Identification‐Labeled Abnormal Potential Areas in Patients With Persistent Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. 2026. doi:10.1111/jce.70400

BibTeX
@article{Ito2026,
  author = {Ito, Kazuki and Naruse, Yoshihisa and Tokonami, Yuki and Kaneko, Yutaro and Sano, Makoto and Maekawa, Yuichiro},
  title = {Detection of Spatio‐Temporal Dispersion Electrograms Using Complex Signal Identification‐Labeled Abnormal Potential Areas in Patients With Persistent Atrial Fibrillation},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  doi = {10.1111/jce.70400}
}
Kostenlos starten →