EUVIMEDEUVIMED entdecken
Crossref

An experimentally calibrated nanodosimetry-based framework for predicting LET-dependent relative biological effectiveness in proton boron capture therapy

Junxiang Wu iD, Zhencen He, Zhao Sun, Lang Dong iD, Tianle Wang, Jiajun Kang, Liyuan Deng, Zhuohang He, Xianliang Wang, Lintao Li, Tianli Qiu, Da Zhang und 3 weitere

Physics in Medicine & Biology · 14.11.2026 · 71 (21) · 215015

DOI: 10.1088/1361-6560/aeb797 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 03.11.2026. Verfasst von Junxiang Wu und 14 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Radiation Physics and Technology of Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University, Chengdu…. Hauptthemen laut MEDLINE: Proton Therapy, Boron Neutron Capture Therapy, Linear Energy Transfer, Radiometry. Die Arbeit nennt 37 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective . Proton boron capture therapy (PBCT) studies focus on physical dose enhancement or biological observations, while quantitative prediction of biological effectiveness remains limited. This study aimed to establish a framework combining Monte Carlo (MC) simulation, nanodosimetry, and radiobiological experiments to evaluate the relative biological effectiveness (RBE) of PBCT. Approach . Geant4-based MC simulations and a pre-calculated nanodosimetric database were used to determine mixed-field nanodosimetric parameters, including M 1 , M 2 , and F 2 . Clonogenic survival experiments were performed using a clinical 70 MeV proton beam and a 6 MV photon beam. U-87 MG cells were irradiated with photons, protons, and PBCT at 0, 2, 4, 6, and 8 Gy using boronophenylalanine (BPA, 21.0 ppm 11 B). Survival data were fitted with the linear–quadratic model, and the resulting α and β values were used to optimize the logistic nanodosimetry model (LNDM) for depth-dependent RBE prediction. Main results . The LNDM, combined with MC-derived nanodosimetric parameters and experimental survival data, reproduced the measured radiobiological response with differences in α and β below 0.5% at the experimental cell position, corresponding to a water-equivalent depth of 3.9 cm and located on the rising edge of the Bragg peak. PBCT consistently exhibited higher α and RBE values than proton irradiation across the investigated linear energy transfer (LET) range. At 3.9 cm, PBCT increased RBE by 8.7% compared with protons. For the 70 MeV beam, PBCT yielded α = 0.116 Gy −1 , β = 0.023 Gy −2 , and RBE = 1.25, compared with α = 0.076 Gy −1 , β = 0.023 Gy −2 , and RBE = 1.15 for proton therapy. Significance . An experimentally calibrated framework integrating MC simulation, nanodosimetry, radiobiological experiments, and the LNDM was established for LET-dependent PBCT RBE prediction based on biological calibration data. PBCT showed consistently higher RBE than proton therapy, with a greater advantage at higher LET, supporting future biological optimization of PBCT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Proton TherapyBoron Neutron Capture TherapyLinear Energy TransferRadiometryNanotechnologyRelative Biological EffectivenessMonte Carlo MethodHumansCell Line, TumorCalibrationCell Survival

Stichwörter der Autor:innen

Geant4PBCTRBEU-87 MG cellsnanodosimetric parameters

Autor:innen und Institutionen

  • Key Laboratory of Radiation Physics and Technology of Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University, Chengdu 610064, People's Republic of China.
  • Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Radiation Oncology Key Laboratory of Sichuan Province, Chengdu 610041, People's R…

ORCID-Profile: Junxiang Wu, Lang Dong

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Wu, J., He, Z., Sun, Z., Dong, L., Wang, T., Kang, J., Deng, L., He, Z., Wang, X., Li, L., Qiu, T., Zhang, D., Zhao, G., Lu, S., & Hu, Z. (2026). An experimentally calibrated nanodosimetry-based framework for predicting LET-dependent relative biological effectiveness in proton boron capture therapy. Physics in Medicine & Biology, 71(21), 215015. https://doi.org/10.1088/1361-6560/aeb797

Vancouver

Wu J, He Z, Sun Z, Dong L, Wang T, Kang J, et al. An experimentally calibrated nanodosimetry-based framework for predicting LET-dependent relative biological effectiveness in proton boron capture therapy. Physics in Medicine & Biology. 2026;71(21):215015. doi:10.1088/1361-6560/aeb797

BibTeX
@article{Wu2026,
  author = {Wu, Junxiang and He, Zhencen and Sun, Zhao and Dong, Lang and Wang, Tianle and Kang, Jiajun and Deng, Liyuan and He, Zhuohang and Wang, Xianliang and Li, Lintao and Qiu, Tianli and Zhang, Da and Zhao, Guoqiang and Lu, Shun and Hu, Zhimin},
  title = {An experimentally calibrated nanodosimetry-based framework for predicting LET-dependent relative biological effectiveness in proton boron capture therapy},
  journal = {Physics in Medicine & Biology},
  year = {2026},
  volume = {71},
  number = {21},
  pages = {215015},
  doi = {10.1088/1361-6560/aeb797}
}
Kostenlos starten →