Dimensionality reduction for partial-volume correction in quantitative SPECT
Physics in Medicine & Biology · 14.11.2026 · 71 (21) · 215016
DOI: 10.1088/1361-6560/aeb644 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 03.11.2026. Verfasst von Johan Gustafsson und 2 weiteren Autor:innen. Beteiligte Einrichtung: Medical Radiation Physics, Lund, Lund University, Lund, Sweden. Hauptthemen laut MEDLINE: Tomography, Emission-Computed, Single-Photon, Image Processing, Computer-Assisted. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Mrs Berta Kamprad’s Foundation, Region Skåne, Swedish Cancer Society.
Abstract (Originalsprache)
Objective . The aim of this paper is to develop a method for region-based post-reconstruction partial-volume correction (PVC) of single photon emission computed tomography (SPECT) images, which explicitly estimates the mean activity concentration in regions without assuming strict intra-regional uniformity. Approach . PVC was applied to 177 Lu-SPECT images obtained from the simulation of eight anthropomorphic phantoms as well as two example patients. Both sets of data were reconstructed using OS-EM with ten subsets and up to 40 iterations, including compensation for attenuation, scatter, and spatial resolution. Reconstructed images were deconvolved using the van Cittert algorithm and Lucy–Richardson algorithm, both implemented on images represented as standard cuboid voxels or as regional voxels, consisting of regions defined from whole-image segmentation. Methods embedding regional voxels were applied both assuming region-wise uniform activity concentration and incorporating perturbations in the form of cosine series to relax the uniformity assumption. For comparison, images were also processed with the iterative Yang method and MIRD recovery coefficients. Evaluation was performed with respect to the estimated activity concentration for kidneys, spleen, and tumours, as well as the total activity in the images. Main results . Mean activity-concentration errors prior to PVC were (−22.6 ± 11.5) %, (−13.8 ± 2.1) %, and (−7.4 ± 2.8) % for tumours, kidneys, and spleen, respectively. Region-perturbed van Cittert deconvolution with order 4 reduced these errors to (2.3 ± 7.7) %, (0.3 ± 2.2) %, and (4.0 ± 1.6) % while the errors for region-perturbed Lucy-Richardson deconvolution of order 4 were (0.3 ± 8.0) %, (0.0 ± 1.6) %, (2.6 ± 0.5) %. Corresponding results for the iterative Yang method were (2.8 ± 21) %, (−0.3 ± 2.1) %, and (3.8 ± 2.4) % and using MIRD recovery coefficients (−5.0 ± 14.2) %, (−7.1 ± 1.9) %, and (−0.6 ± 3.1) %. Significance . Region-based PVC improves the accuracy of quantitative SPECT, and the inclusion of cosine perturbations allows for a gradual relaxation of the uniformity assumption.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Medical Radiation Physics, Lund, Lund University, Lund, Sweden.
- Radiation Physics, Department of Haematology, Oncology, and Radiation Physics, Skåne University Hospital, Lund, Sweden.
ORCID-Profile: Johan Gustafsson, Erik Larsson, Katarina Sjögreen Gleisner
Förderung
- Mrs Berta Kamprad’s Foundation
- Region Skåne
- Swedish Cancer Society
Zitieren
APA
Gustafsson, J., Larsson, E., & Sjögreen Gleisner, K. (2026). Dimensionality reduction for partial-volume correction in quantitative SPECT. Physics in Medicine & Biology, 71(21), 215016. https://doi.org/10.1088/1361-6560/aeb644
Vancouver
Gustafsson J, Larsson E, Sjögreen Gleisner K. Dimensionality reduction for partial-volume correction in quantitative SPECT. Physics in Medicine & Biology. 2026;71(21):215016. doi:10.1088/1361-6560/aeb644
BibTeX
@article{Gustafsson2026,
author = {Gustafsson, Johan and Larsson, Erik and Sjögreen Gleisner, Katarina},
title = {Dimensionality reduction for partial-volume correction in quantitative SPECT},
journal = {Physics in Medicine & Biology},
year = {2026},
volume = {71},
number = {21},
pages = {215016},
doi = {10.1088/1361-6560/aeb644}
}