EUVIMEDEuropean Health Evidence
Uhr 7/7Sources Journal Tree
Easy Demo

Lokaler Crossref-Datenbestand · journal-article

GATE/Geant4 simulation of key dosimetric correction factors for alanine dosimetry in 12 C ion beams

Pascal Saße, Jessica Stolzenberg, Kilian-Simon Baumann, Vanessa Delfs, Ralf-Peter Kapsch, Hugo Palmans, Bjoern Poppe, Hui Khee Looe

Physics in Medicine & Biology · 2026

Vollständiger Abstract

Worum geht es in dieser Arbeit?

Abstract Objective: Alanine has been used frequently as a reference dosimeter in clinical dosimetry. However, its high LET dependence poses a challenge for practical applications. Determination of the required beam quality correction factors requires Monte Carlo simulations. This makes the application of alanine infeasible if dedicated Monte Carlo tools or computing resources are not available. This work sets out to determine generalized alanine correction factors in clinical 12 C beams. Approach: Mathematical expressions were established to parametrize dosimetric correction factors. Spectral fluences in 429 MeV/u mono energetic and a range modulated 278 MeV/u 12 C beams were simulated at multiple depths along the central beam axis using GATE/Geant4. Beam quality correction factors were determined under Spencer-Attix conditions in water and in alanine-paraffin pellets. Main results: Analytical expressions for the water-to-medium stopping-power ratios and the beam quality correction factor were obtained. The analytical expressions represent correction factors that are well within the confidence interval, except at the Bragg peak and the distal edge of the SOBP.These points were found to be unsuitable for measurement using alanine standard dosimeters due to the high perturbation factors. Significance: The results allow alanine dosimetry to be performed for mono-energetic and range-modulated beams without prior Monte Carlo simulations. This greatly reduces the effort associated with practical alanine dosimetry.

Bibliografischer Nachweis

Publikationsdaten

Autor:innen
Pascal Saße, Jessica Stolzenberg, Kilian-Simon Baumann, Vanessa Delfs, Ralf-Peter Kapsch, Hugo Palmans, Bjoern Poppe, Hui Khee Looe
Quelle
Physics in Medicine & Biology
Publikation
2026-01-01
Band / Ausgabe
Nicht angegeben
Seiten
Nicht angegeben
ISSN / ISBN
0031-9155, 1361-6560
Zitationen
0 laut Crossref
Referenzen
0 hinterlegt

Zitieren

Zitierfähiger Nachweis

Pascal Saße, Jessica Stolzenberg, Kilian-Simon Baumann, Vanessa Delfs, Ralf-Peter Kapsch, Hugo Palmans, Bjoern Poppe, Hui Khee Looe (2026). GATE/Geant4 simulation of key dosimetric correction factors for alanine dosimetry in 12 C ion beams. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/aea1d6
RIS BibTeX CSL-JSON

Kontext

Themen, Förderung und Nutzung

Lizenzhinweise: Lizenz 1 · Lizenz 2