EUVIMEDEuropean Health Evidence
Uhr 7/7Sources Journal Tree
Easy Demo

Lokaler Crossref-Datenbestand · journal-article

Three-point center-of-gravity calculation for crosshair light sharing PET detector

Eiji Yoshida, Fujino Obata, Taiga Yamaya

Physics in Medicine & Biology · 2026

Vollständiger Abstract

Worum geht es in dieser Arbeit?

Abstract Objective. The crosshair light-sharing (CLS) PET detector acquires time-of-flight (TOF) and depth-of-interaction (DOI) information by looping scintillation light through a window at the top of the crystals and distributing it to two photosensors, but light is typically detected by an average of six photosensors, making center-of-gravity (CoG) calculation essential for crystal identification. Approach. In this work, an improved CLS detector achieved a shorter coincidence resolving time (CRT) by employing a reflector with a thickness comparable to the 0.2 mm photosensor gap, together with a new CoG calculation method specialized for the CLS detector to address the problem that weak signals at deep interaction positions fall below the noise level caused by light leakage. In the improved CLS detector, the reflector thickness was set to 188 μm to approximate the photosensor gap, and the crystal size was optimized accordingly. The developed three-point CoG (3P-CoG) method removes light that does not contribute to position detection by using only the three outputs with the highest detected energies. Main results. For the improved CLS detector, the new reflective material increased light output and contributed to an improvement in the CRT. Applying 3P-CoG enabled clearer separation of all crystals regardless of interaction depth. Furthermore, 3P-CoG improves the DOI resolution by approximately 10%. Finally, 3P-CoG contributes to data-volume reduction because the crystal response remains stable even when the energy threshold is increased. Significance. These results show that a simple 3P-CoG algorithm can improve interaction-position estimation in CLS detectors.

Bibliografischer Nachweis

Publikationsdaten

Autor:innen
Eiji Yoshida, Fujino Obata, Taiga Yamaya
Quelle
Physics in Medicine & Biology
Publikation
2026-01-01
Band / Ausgabe
Nicht angegeben
Seiten
Nicht angegeben
ISSN / ISBN
0031-9155, 1361-6560
Zitationen
0 laut Crossref
Referenzen
0 hinterlegt

Zitieren

Zitierfähiger Nachweis

Eiji Yoshida, Fujino Obata, Taiga Yamaya (2026). Three-point center-of-gravity calculation for crosshair light sharing PET detector. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/aea1bd
RIS BibTeX CSL-JSON

Kontext

Themen, Förderung und Nutzung

Lizenzhinweise: Lizenz 1 · Lizenz 2