Reconstructing delivered dose in real time: a beam physics-embedded, language-model-driven approach
Physics in Medicine & Biology · 28.08.2026 · 71 (16) · 165007
DOI: 10.1088/1361-6560/ae95ab ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 18.08.2026. Verfasst von Yuli Wang und 11 weiteren Autor:innen. Beteiligte Einrichtung: Icahn School of Medicine at Mount Sinai, New York, NY, United States of America. Hauptthemen laut MEDLINE: Radiation Dosage, Radiotherapy Planning, Computer-Assisted. Die Arbeit nennt 47 Literaturangaben.
Abstract (Originalsprache)
Objective. To develop a fast and accurate physics-informed framework for real-time three-dimensional dose reconstruction directly from machine delivery beams for adaptive radiotherapy and intra-fraction dose monitoring. Approach. We propose a two-stage beam physics-driven dose reconstruction framework that integrates machine photon beam characteristics into fluence-to-dose estimation. In Stage 1, beam-related physical characteristics, including beam profiles and percent depth dose, are extracted from the institutional beam database using a large language model (LLM) assistant tuned on beam commissioning guidelines and encoded as beam-specific priors. In Stage 2, beam-wise fluence-to-dose reconstruction is performed in beam-eye-view space using a multimodal neural network that incorporates BEV-aligned CT images, optimal fluence, and the LLM-derived beam priors. Training uses a composite physics-aware loss, and performance is evaluated using two-dimensional and three-dimensional gamma analysis. Main Results. The study included 180 lung radiotherapy patients for model development and internal evaluation, and an external prostate cohort of 5 patients for cross-site testing. The predicted dose distributions showed strong agreement with reference dose maps, with residual errors mainly confined to low-dose regions and within ± 3 Gy relative to a maximum dose of approximately 75 Gy. The proposed framework achieved a mean 3D gamma passing rate (3%, 2 mm/10%) of 0.975 ± 0.056 , outperforming 3D U-Net ( 0.931 ± 0.113 ), Dose-Net ( 0.939 ± 0.120 ), and CLIP-UNet ( 0.945 ± 0.087 ) ( p < 0.05 ). The corresponding mean 2D gamma passing rate was 0.962 ± 0.073 . External testing achieved a gamma passing rate of 0.953 ± 0.088 . The model required approximately 6.3 seconds to reconstruct a 9-field treatment plan. Significance. By incorporating LLM-encoded beam physics into a multimodal dose reconstruction framework, this method improves dosimetric accuracy over existing learning-based approaches while maintaining rapid inference, supporting its potential for adaptive radiotherapy and real-time three-dimensional in vivo dosimetry.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Icahn School of Medicine at Mount Sinai, New York, NY, United States of America.
- University of Nebraska Medical Center, Omaha, United States of America.
Zitieren
APA
Wang, Y., Wang, J., Zhang, J., Sun, Y., Chao, M., Xia, J., Liu, R., Wang, S., Lei, Y., Goodman, K. A., Liu, T., & Lei, Y. (2026). Reconstructing delivered dose in real time: a beam physics-embedded, language-model-driven approach. Physics in Medicine & Biology, 71(16), 165007. https://doi.org/10.1088/1361-6560/ae95ab
Vancouver
Wang Y, Wang J, Zhang J, Sun Y, Chao M, Xia J, et al. Reconstructing delivered dose in real time: a beam physics-embedded, language-model-driven approach. Physics in Medicine & Biology. 2026;71(16):165007. doi:10.1088/1361-6560/ae95ab
BibTeX
@article{Wang2026,
author = {Wang, Yuli and Wang, Jing and Zhang, Jiahan and Sun, Yuhang and Chao, Ming and Xia, Junyi and Liu, Ruirui and Wang, Shuo and Lei, Yu and Goodman, Karyn A and Liu, Tian and Lei, Yang},
title = {Reconstructing delivered dose in real time: a beam physics-embedded, language-model-driven approach},
journal = {Physics in Medicine & Biology},
year = {2026},
volume = {71},
number = {16},
pages = {165007},
doi = {10.1088/1361-6560/ae95ab}
}
EUVIMED