EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

TOPAS-based 4D Monte Carlo simulation of transit dose in esophageal HDR brachytherapy: a phantom study

F Moradi iD, A Taheri iD, R Boudaghi Malidarreh iD, H A Abdul-Rashid iD

Physics in Medicine & Biology · 2025

DOI: 10.1088/1361-6560/ae0dec ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics in Medicine & Biology, 2025. Verfasst von F Moradi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Imaging, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia. Hauptthemen laut MEDLINE: Monte Carlo Method, Brachytherapy, Phantoms, Imaging, Esophageal Neoplasms. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective. Intraluminal high-dose-rate (HDR) brachytherapy is a well-established treatment modality for esophageal cancer, where a radioactive source moves through a catheter to deliver dose at discrete dwell positions. However, during the source’s transit phase non-negligible dose may be delivered to surrounding healthy tissues. This study utilizes the time-dependent (4D) Monte Carlo (MC) simulation approach to quantify the transit dose to organs at risks (OARs) during esophageal brachytherapy using the TOPAS tool. Approach. A simplified yet anatomically representative male anthropomorphic phantom was modeled in TOPAS, incorporating key anatomical structures including the esophagus, trachea, spinal cord, pharynx, and other OARs. The motion of an Ir-192 HDR source was dynamically simulated through a brachytherapy catheter, with source acceleration and deceleration explicitly modeled to reflect clinical delivery. Focusing on a 6 cm tumor in the upper esophagus, absorbed doses were calculated under varying conditions: constant versus variable source speeds and differing numbers of dwell points, to evaluate the dosimetric impact of source motion. Main results. Compared to static simulations that neglect source movement, the inclusion of realistic source motion led to a substantial increase in dose to the tumor itself, up to 31%. Transit dose to OARs along the catheter path and those adjacent to the esophagus, such as the pre-pharyngeal region and pharynx, reached up to 11.7% of the tumor dose under variable speed profiles. These results reveal significant underestimation in static dose calculations, highlighting the importance of accounting for source motion. Significance. This study underscores the dosimetric importance of accounting for source transit in HDR brachytherapy and demonstrates the value of TOPAS’s time-feature for conducting 4D MC simulations of realistic source motion. The findings indicate that transit dose can contribute substantially to overall dose distributions and should be considered in treatment planning, particularly for tumors situated in anatomically complex or radiosensitive regions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Monte Carlo MethodBrachytherapyPhantoms, ImagingEsophageal NeoplasmsRadiation DosageEsophagusRadiotherapy DosageHumansOrgans at RiskMaleRadiotherapy Planning, Computer-AssistedTime Factors

Stichwörter der Autor:innen

4D Monte Carlo simulationTOPASbrachytherapytime featuretransit dose

Autor:innen und Institutionen

  • Department of Biomedical Imaging, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia.
  • Center for Fiber Networking and Communication, COE for Intelligent Network, Multimedia University, Cyberjaya, Malaysia.
  • Applied Physics and Radiation Technologies Group, CCDCU, Faculty of Engineering and Technology, Sunway University, Bandar Sunway, Selangor, Malaysia.
  • Institute of Physics and Technology, Ural Federal University, Yekaterinburg 620002, Russia.
  • Faculty of Engineering Technology, University College TATI (UC TATI), 24000 Kemaman, Terengganu, Malaysia.

ORCID-Profile: F Moradi, A Taheri, R Boudaghi Malidarreh, H A Abdul-Rashid

Zitieren

APA

Moradi, F., Taheri, A., Malidarreh, R. B., & Abdul-Rashid, H. A. (2025). TOPAS-based 4D Monte Carlo simulation of transit dose in esophageal HDR brachytherapy: a phantom study. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/ae0dec

Vancouver

Moradi F, Taheri A, Malidarreh RB, Abdul-Rashid HA. TOPAS-based 4D Monte Carlo simulation of transit dose in esophageal HDR brachytherapy: a phantom study. Physics in Medicine & Biology. 2025. doi:10.1088/1361-6560/ae0dec

BibTeX
@article{Moradi2025,
  author = {Moradi, F and Taheri, A and Malidarreh, R Boudaghi and Abdul-Rashid, H A},
  title = {TOPAS-based 4D Monte Carlo simulation of transit dose in esophageal HDR brachytherapy: a phantom study},
  journal = {Physics in Medicine & Biology},
  year = {2025},
  doi = {10.1088/1361-6560/ae0dec}
}
Kostenlos starten →