Evaluation of skin dose robustness in breast radiotherapy using VMAT planning technique: a phantom-based surface dosimetry study
Physics in Medicine & Biology · 14.08.2026 · 71 (15) · 155007
DOI: 10.1088/1361-6560/ae8ca5 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Physics in Medicine & Biology, online erschienen am 03.08.2026. Verfasst von Dohyeon Yoo und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine & Heavy Ion Therapy Research Institute, Yonsei Universi…. Hauptthemen laut MEDLINE: Phantoms, Imaging, Skin, Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated. Die Arbeit nennt 42 Literaturangaben. Gefördert von: National Research Foundation of Korea.
Abstract (Originalsprache)
Objective. Minor anatomical changes from evolving edema during breast radiotherapy can compromise skin dose, particularly for volumetric modulated arc therapy (VMAT). This study experimentally evaluated the robustness of conventional, skin-flash, and robust-optimization-based VMAT techniques against simulated contour variations using phantom-based surface dosimetry. Approach. Two configurations of an anthropomorphic phantom simulated clinical scenarios: with a breast attachment (large/reconstructed) and without (small/postmastectomy flat chest wall). Four plans were compared: 3D-CRT, conventional VMAT, VMAT with skin-flash, and VMAT with robust optimization (RO). Plan robustness was assessed via treatment planning system (TPS) simulations and physical optically stimulated luminescence dosimeter (OSLD) measurements at five surface points. To simulate controlled rigid surface contour change, the couch was shifted anterior-posteriorly by ± 2 , ± 4 , and ± 6 mm as a simplified surrogate for edema-induced variations. Shifted OSLD measurements were normalized to the 0 mm baseline, and absolute dose deviations were evaluated against the 3D-CRT reference. Main Results. TPS simulations suggested VMAT with skin-flash offered the greatest stability; however, physical measurements showed the opposite. Conventional VMAT was more variable than 3D-CRT (SD 9.47% vs 3.62% at ± 6 mm), and the evaluated VMAT with skin-flash implementation was the least robust (SD 12.60%; worst-case minimum dose 62.49% with 75% of points outside ± 5 % ), despite its favorable TPS prediction. In contrast, VMAT with RO approached the stability of 3D-CRT (SD 5.48%) and showed even smaller deviations than 3D-CRT in the phantom with a breast attachment. Significant. These physical measurements demonstrate that, contrary to TPS predictions, the evaluated VMAT with skin-flash implementation does not ensure skin-dose robustness, whereas VMAT with RO substantially improved robustness to a level comparable to that of 3D-CRT, with the greatest benefit observed in the phantom with a breast attachment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine & Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul 03722, Republic of Korea.
ORCID-Profile: Dohyeon Yoo, Chae-Seon Hong, Deok Kim, Hojin Kim
Förderung
- National Research Foundation of Korea
Zitieren
APA
Yoo, D., Hong, C. S., Jeong, H., Kim, D., Kim, Y., Kim, W. S., Park, R. H., Park, S., Choi, S. H., Chang, J. S., & Kim, H. (2026). Evaluation of skin dose robustness in breast radiotherapy using VMAT planning technique: a phantom-based surface dosimetry study. Physics in Medicine & Biology, 71(15), 155007. https://doi.org/10.1088/1361-6560/ae8ca5
Vancouver
Yoo D, Hong CS, Jeong H, Kim D, Kim Y, Kim WS, et al. Evaluation of skin dose robustness in breast radiotherapy using VMAT planning technique: a phantom-based surface dosimetry study. Physics in Medicine & Biology. 2026;71(15):155007. doi:10.1088/1361-6560/ae8ca5
BibTeX
@article{Yoo2026,
author = {Yoo, Dohyeon and Hong, Chae-Seon and Jeong, Hoyeon and Kim, Deok and Kim, YunJoong and Kim, Woo Shik and Park, Ryeong Hwang and Park, Sangjoon and Choi, Seo Hee and Chang, Jee Suk and Kim, Hojin},
title = {Evaluation of skin dose robustness in breast radiotherapy using VMAT planning technique: a phantom-based surface dosimetry study},
journal = {Physics in Medicine & Biology},
year = {2026},
volume = {71},
number = {15},
pages = {155007},
doi = {10.1088/1361-6560/ae8ca5}
}