EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dosimetric evaluation of systematic source position uncertainty along the source path and robust planning during MRI‐only cervical HDR brachytherapy

Amritpal Singh, Raffi Karshafian, Ananth Ravi, Moti Raj Paudel iD

Journal of Applied Clinical Medical Physics · 2026

DOI: 10.1002/acm2.70810 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Amritpal Singh und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, Toronto Metropolitan University, Toronto, Ontario, Canada. Hauptthemen laut MEDLINE: Brachytherapy, Uterine Cervical Neoplasms, Radiotherapy Planning, Computer-Assisted, Magnetic Resonance Imaging. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The knowledge of the dosimetric impact of systematic source position uncertainty and the use of a methodology for robust treatment planning against such uncertainty can help improve the quality of treatment plans, during MR‐only cervical brachytherapy treatment.

Purpose

To assess the dosimetric impact of systematic source position uncertainty along the source path and evaluate strategies to minimize it during MRI‐only cervical high‐dose‐rate (HDR) brachytherapy treatment planning.

Methods

Treatment plans from 22 cervical cancer patients (FIGO stages IB2–IVA; 11 intracavitary brachytherapy (ICBT), 11 interstitial brachytherapy (ISBT)) were retrospectively analyzed. Positional uncertainty was modeled by systematically shifting the source position (± 1 to ± 5 mm with 0 mm as the reference position) within applicators along the source path in the original plans. Dosimetric parameters, HRCTV_D90 and D 2cc for organs at risk (OARs), were computed for each source position. Statistical significance was assessed via paired t‐test and Wilcoxon signed‐rank test. Targeted plans exceeding dosimetric limits for OARs were re‐optimized by modifying dwell times or gradients within 1 cm of the targeted OAR to improve the variability and overall OAR dosimetry.

Results

Significant dosimetric changes were observed for bladder, sigmoid (all shift positions; p ≤ 0.001) and rectum (1 to 5 mm; p ≤ 0.04) in ICBT, and for all OARs (all shift positions; p ≤ 0.003) in ISBT. HRCTV_D90 was significantly affected in ICBT from ‐2 to ‐5 mm ( p ≤ 0.042) and at all shifts ( p ≤ 0.033) except at ‐1 and ‐2 mm in ISBT. Within ± 5 mm shift range, the mean (maximum) drop in HRCTV_D90 and increase in OARs (bladder, bowel, rectum and sigmoid) D 2cc were up to −2.0 ± 1.9(−5.4)% and (6.0 ± 3.4(13.6)%, 0.5 ± 2.5(5.5)%, 2.2 ± 2.7(7.4)% and 1.8 ± 1.2(4.2)%) for ICBT, and ‐6.2 ± 1.4(‐11.9)% and (5.2 ± 4.6(17.2)%, 1.3 ± 0.9(3.0)%, 4.6 ± 2.5(7.6)% and 6.6 ± 3.6(13.8)%) for ISBT, respectively. Re‐optimized plans showed improved robustness of dosimetry against source positional uncertainty for the targeted OAR with the same or better dosimetry for other OARs and HRCTV. The strategies to obtain this robustness were patient and applicator‐type dependent.

Conclusion

Systematic source position uncertainty significantly influences dosimetry in MRI‐only cervical HDR brachytherapy. Adjusting dwell times and gradients near the targeted OAR could minimize this effect.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrachytherapyUterine Cervical NeoplasmsRadiotherapy Planning, Computer-AssistedMagnetic Resonance ImagingHumansRadiotherapy DosageOrgans at RiskFemaleRetrospective StudiesUncertaintyRadiotherapy, Intensity-ModulatedPrognosis

Stichwörter der Autor:innen

MRIcervical cancerhigh‐dose‐rateinterstitial brachytherapyintracavitary

Autor:innen und Institutionen

  • Department of Physics, Toronto Metropolitan University, Toronto, Ontario, Canada.
  • Institute for Biomedical Engineering, Science and Technology (IBEST), Toronto, Ontario, Canada.
  • Department of Medical Physics, Sunnybrook Health Science Centre, Toronto, Ontario, Canada.
  • Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada.

ORCID-Profile: Moti Raj Paudel

Zitieren

APA

Singh, A., Karshafian, R., Ravi, A., & Paudel, M. R. (2026). Dosimetric evaluation of systematic source position uncertainty along the source path and robust planning during MRI‐only cervical HDR brachytherapy. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70810

Vancouver

Singh A, Karshafian R, Ravi A, Paudel MR. Dosimetric evaluation of systematic source position uncertainty along the source path and robust planning during MRI‐only cervical HDR brachytherapy. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70810

BibTeX
@article{Singh2026,
  author = {Singh, Amritpal and Karshafian, Raffi and Ravi, Ananth and Paudel, Moti Raj},
  title = {Dosimetric evaluation of systematic source position uncertainty along the source path and robust planning during MRI‐only cervical HDR brachytherapy},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  doi = {10.1002/acm2.70810}
}
Kostenlos starten →