A Gaussian fitting-based analysis method for multiple image radiography with integrated angular calibration, MIR2

Farangis Foroughi iD, Gurpreet Aulakh iD, David Krapohl iD, Börje Norlin iD, Ralf Henrik Menk iD, Dean Chapman iD

Physics in Medicine & Biology · 07.12.2025 · 70 (23) · 235032

DOI: 10.1088/1361-6560/ae22ba ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 04.12.2025. Verfasst von Farangis Foroughi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics and Engineering Physics, College of Arts and Science, University of Saskatchewan, 116 Science Place, Saskatoon, Saskatchewan S7…. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Radiography. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council (NSERC) Discovery, Canadian Light Source, Canada Foundation for Innovation (CFI).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Multiple image radiography (MIR) is an X-ray phase-contrast technique that enhances soft-tissue visibility by rejecting Compton scatter and capturing absorption, refraction, and ultra-small-angle x-ray scattering (USAXS) signals. Conventional MIR workflows depend on normalization between object and reference datasets and precise angular alignment, making them sensitive to drift and prone to artifacts such as banding. We present an improved analysis framework, MIR2, which eliminates normalization and alignment by independently analyzing object and reference data and applying angular calibration based on the dynamical theory of diffraction. Like MIR, it employs pixel-wise Gaussian fitting of angular intensity profiles, but the MIR2 pipeline is simpler, less error-prone, and more robust against alignment-related artifacts. Importantly, artifact suppression is achieved intrinsically, without relying on additional correction algorithms. MIR2 was implemented in Python and validated at the BMIT beamline (Canadian Light Source, 33.3 keV, Si(220) double-crystal monochromator) using both test objects (PMMA step wedge, layered paper) and in vivo imaging of a live anesthetized mouse lung. Across both studies, MIR2 produced more stable and artifact-reduced images than MIR. The method simplifies analysis workflows and supports streamlined application of MIR in biomedical and material imaging under dose-limited conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Processing, Computer-AssistedRadiographyAnimalsMiceNormal DistributionCalibrationLung

Stichwörter der Autor:innen

dose-limited imagingmultiple image radiographyphase-based x-ray imagingsoft tissue imaging

Autor:innen und Institutionen

  • Department of Physics and Engineering Physics, College of Arts and Science, University of Saskatchewan, 116 Science Place, Saskatoon, Saskatchewan S7N 5E2, Canada.
  • Department of Computer and Electrical Engineering, Mid Sweden University, Sundsvall, Sweden.
  • Small Animal Clinical Sciences, Western College of Veterinary Medicine, University of Saskatchewan, 52 Campus Drive, Saskatoon, Saskatchewan S7N 5B4, Canada.
  • Elettra Sincrotrone Trieste, S. S. 14 km 163.5, Basovizza 34012, Trieste, Italy.
  • Department Anatomy, Physiology & Pharmacology, College of Medicine, University of Saskatchewan, 107 Wiggins Road, Saskatoon, Saskatchewan S7N 5E5, Canada.

ORCID-Profile: Farangis Foroughi, Gurpreet Aulakh, David Krapohl, Börje Norlin, Ralf Henrik Menk, Dean Chapman

Förderung

  • Natural Sciences and Engineering Research Council (NSERC) Discovery
  • Canadian Light Source
  • Canada Foundation for Innovation (CFI)
  • Canadian Institutes of Health Research (CIHR)
  • Government of Saskatchewan
  • University of Saskatchewan
  • Natural Sciences and Engineering Research Council
  • NSERC

Zitieren

APA

Foroughi, F., Aulakh, G., Krapohl, D., Norlin, B., Menk, R. H., & Chapman, D. (2025). A Gaussian fitting-based analysis method for multiple image radiography with integrated angular calibration, MIR2. Physics in Medicine & Biology, 70(23), 235032. https://doi.org/10.1088/1361-6560/ae22ba

Vancouver

Foroughi F, Aulakh G, Krapohl D, Norlin B, Menk RH, Chapman D. A Gaussian fitting-based analysis method for multiple image radiography with integrated angular calibration, MIR2. Physics in Medicine & Biology. 2025;70(23):235032. doi:10.1088/1361-6560/ae22ba

BibTeX
@article{Foroughi2025,
  author = {Foroughi, Farangis and Aulakh, Gurpreet and Krapohl, David and Norlin, Börje and Menk, Ralf Henrik and Chapman, Dean},
  title = {A Gaussian fitting-based analysis method for multiple image radiography with integrated angular calibration, MIR2},
  journal = {Physics in Medicine & Biology},
  year = {2025},
  volume = {70},
  number = {23},
  pages = {235032},
  doi = {10.1088/1361-6560/ae22ba}
}
Kostenlos starten →