Patient-specific uncertainty calibration of deep learning-based autosegmentation networks for adaptive MRI-guided lung radiotherapy
Physics in Medicine & Biology · 18.05.2025 · 70 (10) · 105018
DOI: 10.1088/1361-6560/add640 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 16.05.2025. Verfasst von Moritz Rabe und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany. Hauptthemen laut MEDLINE: Deep Learning, Radiotherapy, Image-Guided, Lung Neoplasms, Magnetic Resonance Imaging. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Munich Medical & Clinician Scientist Program (MCSP), Stiftung Deutsche Krebshilfe, Deutsche Krebshilfe.
Abstract (Originalsprache)
Objective. Uncertainty assessment of deep learning autosegmentation (DLAS) models can support contour corrections in adaptive radiotherapy (ART), e.g. by utilizing Monte Carlo Dropout (MCD) uncertainty maps. However, poorly calibrated uncertainties at the patient level often render these clinically nonviable. We evaluated population-based and patient-specific DLAS accuracy and uncertainty calibration and propose a patient-specific post-training uncertainty calibration method for DLAS in ART. Approach. The study included 122 lung cancer patients treated with a low-field MR-linac (80/19/23 training/validation/test cases). Ten single-label 3D-U-Net population-based baseline models (BM) were trained with dropout using planning MRIs (pMRIs) and contours for nine organs-at-riks (OARs) and gross tumor volumes (GTVs). Patient-specific models (PS) were created by fine-tuning BMs with each test patient’s pMRI. Model uncertainty was assessed with MCD, averaged into probability maps. Uncertainty calibration was evaluated with reliability diagrams and expected calibration error (ECE). A proposed post-training calibration method rescaled MCD probabilities for fraction images in BM (calBM) and PS (calPS) after fitting reliability diagrams from pMRIs. All models were evaluated on fraction images using Dice similarity coefficient (DSC), 95th percentile Hausdorff distance (HD95) and ECE. Metrics were compared among models for all OARs combined ( n = 163), and the GTV ( n = 23), using Friedman and posthoc-Nemenyi tests ( α = 0.05). Main results. For the OARs, patient-specific fine-tuning significantly ( p < 0.001) increased median DSC from 0.78 (BM) to 0.86 (PS) and reduced HD95 from 14 mm (BM) to 6.0 mm (PS). Uncertainty calibration achieved substantial reductions in ECE, from 0.25 (BM) to 0.091 (calBM) and 0.22 (PS) to 0.11 (calPS) ( p < 0.001), without significantly affecting DSC or HD95 ( p > 0.05). For the GTV, BM performance was poor (DSC = 0.05) but significantly ( p < 0.001) improved with PS training (DSC = 0.75) while uncertainty calibration reduced ECE from 0.22 (PS) to 0.15 (calPS) ( p = 0.45). Significance. Post-training uncertainty calibration yields geometrically accurate DLAS models with well-calibrated uncertainty estimates, crucial for ART applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany.
- Department of Radiotherapy, Division of Imaging & Oncology, University Medical Center Utrecht, Computational Imaging Group for MR diagnostics & therapy, Center for Image Sciences, Utrecht, The Netherlands.
- German Cancer Consortium (DKTK), Partner site Munich, a partnership between DKFZ and LMU University Hospital Munich, Munich, Germany.
- Bavarian Cancer Research Center (BZKF), Munich, Germany.
ORCID-Profile: Moritz Rabe, Ettore F Meliadò, Sebastian N Marschner, Claus Belka, Stefanie Corradini, Cornelis A T van den Berg, Guillaume Landry
Förderung
- Munich Medical & Clinician Scientist Program (MCSP)
- Stiftung Deutsche Krebshilfe
- Deutsche Krebshilfe
Zitieren
APA
Rabe, M., Meliadò, E. F., Marschner, S. N., Belka, C., Corradini, S., van den Berg, C. A. T., Landry, G., & Kurz, C. (2025). Patient-specific uncertainty calibration of deep learning-based autosegmentation networks for adaptive MRI-guided lung radiotherapy. Physics in Medicine & Biology, 70(10), 105018. https://doi.org/10.1088/1361-6560/add640
Vancouver
Rabe M, Meliadò EF, Marschner SN, Belka C, Corradini S, van den Berg CAT, et al. Patient-specific uncertainty calibration of deep learning-based autosegmentation networks for adaptive MRI-guided lung radiotherapy. Physics in Medicine & Biology. 2025;70(10):105018. doi:10.1088/1361-6560/add640
BibTeX
@article{Rabe2025,
author = {Rabe, Moritz and Meliadò, Ettore F and Marschner, Sebastian N and Belka, Claus and Corradini, Stefanie and van den Berg, Cornelis A T and Landry, Guillaume and Kurz, Christopher},
title = {Patient-specific uncertainty calibration of deep learning-based autosegmentation networks for adaptive MRI-guided lung radiotherapy},
journal = {Physics in Medicine & Biology},
year = {2025},
volume = {70},
number = {10},
pages = {105018},
doi = {10.1088/1361-6560/add640}
}
EUVIMED