EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Proton GRID and LATTICE treatment planning techniques for clinical liver SFRT treatments

Jufri Setianegara iD, Ya-Nan Zhu iD, Mingyao Zhu iD, Rajeev Badkul, Tianyu Zhao, Harold Li, Fen Wang, David Akhavan, Hao Gao iD, Yuting Lin iD

Physics in Medicine & Biology · 08.06.2025 · 70 (11) · 115002

DOI: 10.1088/1361-6560/add2cc ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 19.05.2025. Verfasst von Jufri Setianegara und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, United States of America. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Proton Therapy, Dose Fractionation, Radiation, Liver Neoplasms. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, National Cancer Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective . This study aims to develop and evaluate various treatment clinical proton spatially-fractionated-radiotherapy (pSFRT) planning techniques namely proton GRID (pGRID) and LATTICE (pLATTICE). Approach. pSFRT plans (27 Gy(RBE), single-fraction) were initially developed using phantom geometries and created retrospectively for a liver patient previously treated with photon virtual GRID (vGRID). pGRID plans varied in cylinder diameters ( D cyl = 0.4–1.4 cm) and center-to-center distances (c-t-c = 1.7–3.4 cm) and were evaluated by peak-to-valley dose ratios (PVDRs), equivalent uniform dose (EUD), and V 27Gy . D cyl and c-t-c distances matching the vGRID EUD and V 27Gy values guided pLATTICE sphere distributions. Various pLATTICE techniques, including different beam numbers, orientations, and sphere arrangements, were investigated. We also explored using collimating brass apertures to enhance the pGRID PVDR. Main results. pGRID plans with 3.4 cm c-t-c and 0.4 cm D cyl resulted in 2.09% V 27Gy , closely matching vGRID’s 1.50%. The resultant pGRID PVDR was 8.92 compared to vGRID’s 2.7–3.0. PVDRs were affected by spot sizes with reductions of 15.0% with range shifters and 76.0% from 7.5 cm to 27.5 cm depths. The highest PVDR of 4.17 was achieved with two-field pLATTICE plans with favorable beam angles, with a 44.6% reduction with unfavorable beam orientations and up to 24.7% reductions with an increasing number of beams. Non-maximal pLATTICE sphere packing arrangements increases the PVDR with a decrease in V 27Gy warranting further investigation. pSFRT plans reduced the healthy liver V 5Gy by 83.6%–90.7% compared to vGRID. Apertures enhanced the PVDR by 170% at the deepest depths but increased the skin D 0.03cc from 26.77 Gy to 54.66 Gy. Significance and conclusion. We developed pGRID and pLATTICE plans, demonstrating that desired plan metrics was achieved by adjusting the geometrical arrangements of SFRT contours. The relative orientation of these contours with beam entrances was crucial for high-quality SFRT plans. pSFRT plans achieved superior PVDRs and better dose sparing to OARs compared to vGRID plans.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedProton TherapyDose Fractionation, RadiationLiver NeoplasmsLiverHumansRadiotherapy DosagePhantoms, Imaging

Stichwörter der Autor:innen

generalized equivalent uniform dose (gEUD)liver hepatocellular carcinomaproton GRID (pGRID)proton LATTICE (pLATTICE)proton spatially fractionated radiotherapy (pSFRT)radiotherapy

Autor:innen und Institutionen

  • Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, United States of America.
  • Department of Radiation Oncology, University of Kansas Medical Center, Kansas City, Kansas, United States of America.
  • Department of Radiation Oncology, Emory University, Atlanta, Georgia, United States of America.
  • Department of Radiation Oncology, University of South Florida, Tampa, Florida, United States of America.

ORCID-Profile: Jufri Setianegara, Ya-Nan Zhu, Mingyao Zhu, Hao Gao, Yuting Lin

Förderung

  • NCI NIH HHS
  • National Cancer Institute

Zitieren

APA

Setianegara, J., Zhu, Y. N., Zhu, M., Badkul, R., Zhao, T., Li, H., Wang, F., Akhavan, D., Gao, H., & Lin, Y. (2025). Proton GRID and LATTICE treatment planning techniques for clinical liver SFRT treatments. Physics in Medicine & Biology, 70(11), 115002. https://doi.org/10.1088/1361-6560/add2cc

Vancouver

Setianegara J, Zhu YN, Zhu M, Badkul R, Zhao T, Li H, et al. Proton GRID and LATTICE treatment planning techniques for clinical liver SFRT treatments. Physics in Medicine & Biology. 2025;70(11):115002. doi:10.1088/1361-6560/add2cc

BibTeX
@article{Setianegara2025,
  author = {Setianegara, Jufri and Zhu, Ya-Nan and Zhu, Mingyao and Badkul, Rajeev and Zhao, Tianyu and Li, Harold and Wang, Fen and Akhavan, David and Gao, Hao and Lin, Yuting},
  title = {Proton GRID and LATTICE treatment planning techniques for clinical liver SFRT treatments},
  journal = {Physics in Medicine & Biology},
  year = {2025},
  volume = {70},
  number = {11},
  pages = {115002},
  doi = {10.1088/1361-6560/add2cc}
}
Kostenlos starten →