Impact of a novel multilayer imager on metal artifacts in MV-CBCT
Physics in Medicine & Biology · 2023
DOI: 10.1088/1361-6560/ace09a ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, 2023. Verfasst von T C Harris und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Brigham and Women's Hospital, Dana Farber Cancer Institute and Harvard Medical School, Boston, MA, United States of…. Hauptthemen laut MEDLINE: Artifacts, Spiral Cone-Beam Computed Tomography. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, National Cancer Institute.
Abstract (Originalsprache)
Objective . Megavoltage cone-beam computed tomography (MV-CBCT) imaging offers several advantages including reduced metal artifacts and accurate electron density mapping for adaptive or emergent situations. However, MV-CBCT imaging is limited by the poor efficiency of current detectors. Here we examine a new MV imager and compare CBCT reconstructions under clinically relevant scenarios. Approach . A multilayer imager (MLI), consisting of four vertically stacked standard flat-panel imagers, was mounted to a clinical linear accelerator. A custom anthropomorphic pelvis phantom with replaceable femoral heads was imaged using MV-CBCT and kilovoltage CBCT (kV-CBCT). Bone, aluminum, and titanium were used as femoral head inserts. 8 MU 2.5 MV scans were acquired for all four layers and (as reference) the top layer. Prostate and bladder were contoured on a reference CT and transferred to the other scans after rigid registration, from which the structural similarity index measure (SSIM) was calculated. Prostate and bladder were also contoured on CBCT scans without guidance, and Dice coefficients were compared to CT contours. Main results . kV-CBCT demonstrated the highest SSIMs with bone inserts (prostate: 0.86, bladder: 0.94) and lowest with titanium inserts (0.32, 0.37). Four-layer MV-CBCT SSIMs were preserved with bone (0.75, 0.80) as compared to titanium (0.67, 0.74), outperforming kV-CBCT when metal is present. One-layer MV-CBCT consistently underperformed four-layer results across all phantom configurations. Unilateral titanium inserts and bilateral aluminum insert results fell between the bone and bilateral titanium results. Dice coefficients trended similarly, with four-layer MV-CBCT reducing metal artifact impact relative to KV-CBCT to provide better soft-tissue identification. Significance . MV-CBCT with a four-layer MLI showed improvement over single-layer MV scans, approaching kV-CBCT quality for soft-tissue contrast. In the presence of artifact-producing metal implants, four-layer MV-CBCT scans outperformed kV-CBCT by eliminating artifacts and single-layer MV-CBCT by reducing noise. MV-CBCT with a novel multi-layer imager may be a valuable alternative to kV-CBCT, particularly in the presence of metal.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiation Oncology, Brigham and Women's Hospital, Dana Farber Cancer Institute and Harvard Medical School, Boston, MA, United States of America.
- Varian Medical Systems, Baden-Dattwil, Switzerland.
ORCID-Profile: T C Harris, M Jacobson
Förderung
- NCI NIH HHS
- National Cancer Institute
Zitieren
APA
Harris, T. C., Jacobson, M., Myronakis, M., Lehmann, M., Huber, P., Morf, D., Ozoemelam, I., Hu, Y. H., Ferguson, D., Fueglistaller, R., Corral Arroyo, P., & Berbeco, R. I. (2023). Impact of a novel multilayer imager on metal artifacts in MV-CBCT. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/ace09a
Vancouver
Harris TC, Jacobson M, Myronakis M, Lehmann M, Huber P, Morf D, et al. Impact of a novel multilayer imager on metal artifacts in MV-CBCT. Physics in Medicine & Biology. 2023. doi:10.1088/1361-6560/ace09a
BibTeX
@article{Harris2023,
author = {Harris, T C and Jacobson, M and Myronakis, M and Lehmann, M and Huber, P and Morf, D and Ozoemelam, I and Hu, Y H and Ferguson, D and Fueglistaller, R and Corral Arroyo, P and Berbeco, R I},
title = {Impact of a novel multilayer imager on metal artifacts in MV-CBCT},
journal = {Physics in Medicine & Biology},
year = {2023},
doi = {10.1088/1361-6560/ace09a}
}
EUVIMED