Multibeam minimum variance beamforming for ring array ultrasound imaging
Physics in Medicine & Biology · 07.07.2023 · 68 (13) · 135005
DOI: 10.1088/1361-6560/acdd4d ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 23.06.2023. Verfasst von Hao Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Engineering Science, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Signal Processing, Computer-Assisted. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: Anhui Provincial Science and Technology Department, National Key R&D Program of China, National Natural Science Foundation of China.
Abstract (Originalsprache)
Objective . Delay-and-sum (DAS) and minimum variance (MV) are two of the most important beamformers researched in ultrasound imaging. Compared with DAS, MV beamformer is different in respect of the aperture weights calculation, and can enhance the image quality by minimizing interference signal power. Various MV beamformers in linear array are studied, but linear array only provides a limited field of view. Ring array can provide better resolution and a full viewing angle; however, few studies have been explored based on ring array transducers. Approach . In this study, we proposed the multibeam MV (MB-MV) beamformer based on the conventional MV to enhance the image quality in ring array ultrasound imaging. To assess the effectiveness of the proposed approach, we conducted simulations, phantom experiments, and in vivo human experiments to compare MB-MV with DAS and spatial smoothing (SS) MV beamformers. Main results . The results show that the MB-MV method achieves at least 50% enhancement in terms of full width at half maximum compared to the others. Additionally, the MB-MV method improves the contrast ratio by approximate 6 dB and 4 dB compared with DAS and SS MV, respectively. Significance . This work demonstrates the feasibility of MB-MV method for ring array ultrasound imaging, and proves that MB-MV can improve the imaging quality in medical ultrasound imaging. According to our results, MB-MV method provides great potential in distinguishing between lesion and non-lesion areas in clinics, and further promotes the practical application of ring arrays in ultrasound imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Engineering Science, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China.
- Institute of Artificial Intelligence, Hefei Comprehensive National Science Center, Hefei, Anhui 230088, People's Republic of China.
- Department of Ultrasound, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui 230001, People's Republic of China.
ORCID-Profile: Yunhao Zhu, Chao Tian
Förderung
- Anhui Provincial Science and Technology Department
- National Key R&D Program of China
- National Natural Science Foundation of China
- Research Fund of the University of Science and Technology of China
Zitieren
APA
Zhang, H., Zhu, Y., Zhou, B., Liu, S., He, N., & Tian, C. (2023). Multibeam minimum variance beamforming for ring array ultrasound imaging. Physics in Medicine & Biology, 68(13), 135005. https://doi.org/10.1088/1361-6560/acdd4d
Vancouver
Zhang H, Zhu Y, Zhou B, Liu S, He N, Tian C. Multibeam minimum variance beamforming for ring array ultrasound imaging. Physics in Medicine & Biology. 2023;68(13):135005. doi:10.1088/1361-6560/acdd4d
BibTeX
@article{Zhang2023,
author = {Zhang, Hao and Zhu, Yunhao and Zhou, Bowen and Liu, Songde and He, Nianan and Tian, Chao},
title = {Multibeam minimum variance beamforming for ring array ultrasound imaging},
journal = {Physics in Medicine & Biology},
year = {2023},
volume = {68},
number = {13},
pages = {135005},
doi = {10.1088/1361-6560/acdd4d}
}
EUVIMED