EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 4.0

Dual- and multi-energy CT for particle stopping-power estimation: current state, challenges and potential

Ming Yang iD, Patrick Wohlfahrt iD, Chenyang Shen iD, Hugo Bouchard iD

Physics in Medicine & Biology · 2023

DOI: 10.1088/1361-6560/acabfa ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Physics in Medicine & Biology, 2023. Verfasst von Ming Yang und 3 weiteren Autor:innen. Beteiligte Einrichtung: The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, 1515 Holcombe Blvd Houston, TX 77030, United States of America. Hauptthemen laut MEDLINE: Proton Therapy. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 181 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Range uncertainty has been a key factor preventing particle radiotherapy from reaching its full physical potential. One of the main contributing sources is the uncertainty in estimating particle stopping power ( ρ s ) within patients. Currently, the ρ s distribution in a patient is derived from a single-energy CT (SECT) scan acquired for treatment planning by converting CT number expressed in Hounsfield units (HU) of each voxel to ρ s using a Hounsfield look-up table (HLUT), also known as the CT calibration curve. HU and ρ s share a linear relationship with electron density but differ in their additional dependence on elemental composition through different physical properties, i.e. effective atomic number and mean excitation energy, respectively. Because of that, the HLUT approach is particularly sensitive to differences in elemental composition between real human tissues and tissue surrogates as well as tissue variations within and among individual patients. The use of dual-energy CT (DECT) for ρ s prediction has been shown to be effective in reducing the uncertainty in ρ s estimation compared to SECT. The acquisition of CT data over different x-ray spectra yields additional information on the material elemental composition. Recently, multi-energy CT (MECT) has been explored to deduct material-specific information with higher dimensionality, which has the potential to further improve the accuracy of ρ s estimation. Even though various DECT and MECT methods have been proposed and evaluated over the years, these approaches are still only scarcely implemented in routine clinical practice. In this topical review, we aim at accelerating this translation process by providing: (1) a comprehensive review of the existing DECT/MECT methods for ρ s estimation with their respective strengths and weaknesses; (2) a general review of uncertainties associated with DECT/MECT methods; (3) a general review of different aspects related to clinical implementation of DECT/MECT methods; (4) other potential advanced DECT/MECT applications beyond ρ s estimation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Proton TherapyHumansTomography, X-Ray ComputedUncertaintyCalibrationPhantoms, Imaging

Stichwörter der Autor:innen

dual-energy CTmulti-energy CTparticle therapyphoton-counting CTrange uncertaintystopping powertreatment planning

Autor:innen und Institutionen

  • The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, 1515 Holcombe Blvd Houston, TX 77030, United States of America.
  • Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, Boston, MA 02115, United States of America.
  • University of Texas Southwestern Medical Center, Department of Radiation Oncology, 2280 Inwood Rd Dallas, TX 75235, United States of America.
  • Département de physique, Université de Montréal, Complexe des sciences, 1375 Avenue Thérèse-Lavoie-Roux, Montréal, Québec H2V0B3, Canada.
  • Centre de recherche du Centre hospitalier de l'Université de Montréal, 900 Rue Saint-Denis, Montréal, Québec, H2X 0A9, Canada.
  • Département de radio-oncologie, Centre hospitalier de l'Université de Montréal, 1051 Rue Sanguinet, Montréal, Québec H2X 3E4, Canada.

ORCID-Profile: Ming Yang, Patrick Wohlfahrt, Chenyang Shen, Hugo Bouchard

Zitieren

APA

Yang, M., Wohlfahrt, P., Shen, C., & Bouchard, H. (2023). Dual- and multi-energy CT for particle stopping-power estimation: current state, challenges and potential. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/acabfa

Vancouver

Yang M, Wohlfahrt P, Shen C, Bouchard H. Dual- and multi-energy CT for particle stopping-power estimation: current state, challenges and potential. Physics in Medicine & Biology. 2023. doi:10.1088/1361-6560/acabfa

BibTeX
@article{Yang2023,
  author = {Yang, Ming and Wohlfahrt, Patrick and Shen, Chenyang and Bouchard, Hugo},
  title = {Dual- and multi-energy CT for particle stopping-power estimation: current state, challenges and potential},
  journal = {Physics in Medicine & Biology},
  year = {2023},
  doi = {10.1088/1361-6560/acabfa}
}
Kostenlos starten →