EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Interferometric diameter topography calibration of test spheres

Tillman Neupert-Wentz, Guido Bartl, René Schödel

Measurement Science and Technology · 20.11.2026 · 37 (46) · 465001

DOI: 10.1088/1361-6501/aebef2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 18.11.2026. Verfasst von Tillman Neupert-Wentz und 2 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Test spheres as used in the calibration of coordinate measuring machine stylus and other free form measuring devices are typically characterised by a small set of diameters and the sphericity along these diameters. This sparse sampling limits the number of positions where the true diameter is known, reducing the sphere’s utility in calibration. To enhance data density and decrease the uncertainty of calibrations, an extension to PTB’s double-ended interferometer (DEI) (Rau and Schödel 2014 Double-Ended Interferometer for Measuring Gauge Blocks Without Wringing pp 859–62) has been developed (Schödel and Fischedick 2021 Meas. Sci. Technol. 32 084010). This work presents the implementation, measurements and evaluation methods for this extension. First, the DEI including the extension is introduced and the optical setup explained. Then the evaluation methods are presented. The evaluation is performed in two steps. First, pixelwise diameter values are calculated for all measurements performed on a sphere, then, a stitching algorithm is employed to combine a series of measurements to one representation of the sphere surface figure. The evaluation is tested with a measurement series on a 30 mm silicon sphere. The uncertainty budget for a diameter is presented, with a combined standard uncertainty of 20 nm.

Zitieren

APA

Neupert-Wentz, T., Bartl, G., & Schödel, R. (2026). Interferometric diameter topography calibration of test spheres. Measurement Science and Technology, 37(46), 465001. https://doi.org/10.1088/1361-6501/aebef2

Vancouver

Neupert-Wentz T, Bartl G, Schödel R. Interferometric diameter topography calibration of test spheres. Measurement Science and Technology. 2026;37(46):465001. doi:10.1088/1361-6501/aebef2

BibTeX
@article{NeupertWentz2026,
  author = {Neupert-Wentz, Tillman and Bartl, Guido and Schödel, René},
  title = {Interferometric diameter topography calibration of test spheres},
  journal = {Measurement Science and Technology},
  year = {2026},
  volume = {37},
  number = {46},
  pages = {465001},
  doi = {10.1088/1361-6501/aebef2}
}
Kostenlos starten →