An oscillation-based active sensing approach for accurate permittivity characterization of liquid mixtures
Measurement Science and Technology · 21.08.2026 · 37 (33) · 335106
DOI: 10.1088/1361-6501/ae87be ↗Kurz gefasst
Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 17.08.2026. Verfasst von Haoran Sun und 7 weiteren Autor:innen. Die Arbeit nennt 56 Literaturangaben. Gefördert von: Key Open Laboratory of Intelligent Meteorological Observation Technology, China Meteorological Administration, Yunnan Provincial Science and Technology Basic Research Program, Sichuan Provincial Science and Technology Department Project.
Abstract (Originalsprache)
This article presents a novel multi-coupled interdigitated (MC-IDC) resonator integrated with a self-oscillating platform for liquid permittivity sensing. The designed MC-IDC resonator is coupled with an RF amplifier to establish a self-oscillating circuit, which not only provides a concentrated electric field for permittivity sensing but also functions as a self-sustaining microwave source. In the test branch, the MC-IDC resonator also serves as the sensing element. The other branch consists of a voltage-controlled oscillator and an MC-IDC resonator of the same dimensions, remaining free of tested samples. The sensing mechanism is based on the principle of symmetry. When the liquid under test (LUT) is injected into the sensing area of the tested branch, deviations in amplitude and phase of the MC-IDC resonator are observed. The signals from both branches are then fed into a gain/phase detector, which effectively translates their amplitude and phase information into corresponding voltage measurements. By leveraging these two measured voltage sets, the permittivity of the LUT can be systematically computed. This study employs ethanol-water and methanol-water mixtures with concentrations ranging from 0% to 100% as LUTs. The concentration samples are strategically divided, with one half serving as calibration solutions to establish the correlation between the dielectric constant, loss tangent, and the two voltages, while the other half serves as unknown samples for comparative analysis with a commercial dielectric probe. The experimental results indicate that the maximum errors in the complex permittivity of the extracted solution were 2.36% and 2.48%, respectively, with corresponding maximum sensitivities of 3.69 mV/△ ϵ ′ r and 199.09 mV/△tan δ . This system eliminates the need for expensive experimental equipment, such as vector network analyzers and spectrum analyzers, thereby minimizing costs. Its simple design enables simultaneous, high-accuracy measurement of both the real part of permittivity and loss tangent. By integrating with Internet of Things technologies, these advantages position it as an outstanding option for material characterization through wireless networks.
Förderung
- Key Open Laboratory of Intelligent Meteorological Observation Technology, China Meteorological Administration
- Yunnan Provincial Science and Technology Basic Research Program
- Sichuan Provincial Science and Technology Department Project
Zitieren
APA
Sun, H., Yang, W., Han, P., Zhang, F., Xu, J., Liu, D., He, Y., & Du, G. (2026). An oscillation-based active sensing approach for accurate permittivity characterization of liquid mixtures. Measurement Science and Technology, 37(33), 335106. https://doi.org/10.1088/1361-6501/ae87be
Vancouver
Sun H, Yang W, Han P, Zhang F, Xu J, Liu D, et al. An oscillation-based active sensing approach for accurate permittivity characterization of liquid mixtures. Measurement Science and Technology. 2026;37(33):335106. doi:10.1088/1361-6501/ae87be
BibTeX
@article{Sun2026,
author = {Sun, Haoran and Yang, Wenhao and Han, Peifeng and Zhang, Fugui and Xu, Jun and Liu, Dong and He, Yunze and Du, Guohong},
title = {An oscillation-based active sensing approach for accurate permittivity characterization of liquid mixtures},
journal = {Measurement Science and Technology},
year = {2026},
volume = {37},
number = {33},
pages = {335106},
doi = {10.1088/1361-6501/ae87be}
}
EUVIMED