Interdigital capacitor (IDC) based sensitivity enhanced microwave sensor for liquid permittivity characterization
Physica Scripta · 24.07.2026 · 101 (29) · 295501
DOI: 10.1088/1402-4896/ae833b ↗Kurz gefasst
Fachartikel in der Zeitschrift Physica Scripta, online erschienen am 17.07.2026. Verfasst von Sanjeev Sharma und 2 weiteren Autor:innen. Die Arbeit nennt 48 Literaturangaben.
Abstract (Originalsprache)
A planar microwave sensor having enhanced sensitivity is presented to accurately characterize the dielectric properties of liquid samples. Better sensitivity is achieved by including an interdigital capacitor (IDC) within a complementary split-ring resonator (CSRR) structure in the ground plane. An additional vertical slot placed between the IDC fingers, along with two additional slots positioned outside the CSRR–IDC structure, increases the capacitive effect and electric field confinement, which strengthens its interaction with the sample under test (SUT). The proposed sensor has a compact size of 39 × 30 × 0.51 mm 3 , which makes it suitable for integration into portable measurement systems. Further, the dimensions of the cylindrical sample holder are also optimized to maximize the electric-field coupling of the sensor with the SUT. A precise volume of the sample is loaded into the sample holder using a micro pipette, which is positioned above the resonating IDC–CSRR sensing structure. Measurements were carried out using eighteen different liquid samples, having a wide and diversified dielectric range. The proposed sensor achieves an enhanced normalized sensitivity of 3.6% for the full range ( ϵ ′ = 1–111) and 5.27% for the lower range ( ϵ ′ = 1–20). For reliable and accurate estimation of the complex permittivity of unknown samples, a nonlinear regression-based curve-fitting model was developed. The measured S 21 resonant frequency and its notch depth are used as input to the model to estimate the values of unknown samples. Further, the validation of the model is done with a separate set of samples, which generated maximum errors of 4.39% for ϵ ′ and 1.31% for ϵ ″ between the calculated and actual values. The presented results indicate that the sensor can be a potential platform for estimating the liquid permittivity of samples with a wide dielectric range, with enhanced sensitivity and accuracy.
Zitieren
APA
Sharma, S., Singh, M., & Kumar, R. (2026). Interdigital capacitor (IDC) based sensitivity enhanced microwave sensor for liquid permittivity characterization. Physica Scripta, 101(29), 295501. https://doi.org/10.1088/1402-4896/ae833b
Vancouver
Sharma S, Singh M, Kumar R. Interdigital capacitor (IDC) based sensitivity enhanced microwave sensor for liquid permittivity characterization. Physica Scripta. 2026;101(29):295501. doi:10.1088/1402-4896/ae833b
BibTeX
@article{Sharma2026,
author = {Sharma, Sanjeev and Singh, Maninder and Kumar, Rajeev},
title = {Interdigital capacitor (IDC) based sensitivity enhanced microwave sensor for liquid permittivity characterization},
journal = {Physica Scripta},
year = {2026},
volume = {101},
number = {29},
pages = {295501},
doi = {10.1088/1402-4896/ae833b}
}