Simultaneous measurement of rotation angle and axial displacement based on 19-core fiber
Measurement Science and Technology · 10.07.2026 · 37 (27) · 275109
DOI: 10.1088/1361-6501/ae804a ↗Kurz gefasst
Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 07.07.2026. Verfasst von Yan Bai und 7 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Gefördert von: Hebei Province Higher Education Basic Scientific Research Operating Funds, Science and Technology Project of Hebei Education Department.
Abstract (Originalsprache)
A fiber sensing system for the simultaneous measurement of rotation angle and axial displacement, based on 19-core fiber (19CF), is proposed and demonstrated. The proposed system employs two single-mode fibers (SMFs) and a 19CF aligned face-to-face via the ceramic ferrules, forming a tiny air gap. The two SMFs are tightly and side-by-side fixed within the ceramic ferrule, forming an eccentric rotatable structure. The 19CF is fixed within another ceramic ferrule and is installed directly opposite the former. When the ceramic ferrule containing the SMFs rotates, the light-transmitting SMF performs an eccentric circular motion about the axis to realize rotational angle scanning, while the axial displacement of the 19CF is driven by rotating the adjustment sleeve to change the air gap between the two ceramic ferrules. The beam patterns distribution on the end face of the 19CF are captured by a microscope camera. The intensity of each core is extracted by summing the grayscale values of the pixels corresponding to its respective beam spot. Subsequently, a Gaussian fit is performed on the intensity distribution of the core array, enabling the decoupled measurement of rotation angle and axial displacement. The mathematical expectation and standard deviation of the Gaussian fitting curve are used to characterize the rotation angle and axial displacement, respectively. The measurement results of the rotation angle indicate that the experimental data-fitted rotation angle is in good agreement with the given rotation angle. The maximum root mean square error over the full-scale range is 10.79°. For displacement measurement, axial displacement sensing with good linearity ( R 2 = 0.9393), and a resolution of 0.07 mm is achieved within a measurement range of 0.25–1.125 mm. The sensor has advantages such as a simple structure, direct decoupling of angle and displacement, and full-angle continuous measurement.
Förderung
- Hebei Province Higher Education Basic Scientific Research Operating Funds
- Science and Technology Project of Hebei Education Department
Zitieren
APA
Bai, Y., Xue, M., Ma, X., Chen, W., Ma, S., Yang, D., Wang, Y., & Wen, X. (2026). Simultaneous measurement of rotation angle and axial displacement based on 19-core fiber. Measurement Science and Technology, 37(27), 275109. https://doi.org/10.1088/1361-6501/ae804a
Vancouver
Bai Y, Xue M, Ma X, Chen W, Ma S, Yang D, et al. Simultaneous measurement of rotation angle and axial displacement based on 19-core fiber. Measurement Science and Technology. 2026;37(27):275109. doi:10.1088/1361-6501/ae804a
BibTeX
@article{Bai2026,
author = {Bai, Yan and Xue, Mingyang and Ma, Xiaoxin and Chen, Wenlu and Ma, Shichang and Yang, Donglin and Wang, Yanxia and Wen, Xiaodong},
title = {Simultaneous measurement of rotation angle and axial displacement based on 19-core fiber},
journal = {Measurement Science and Technology},
year = {2026},
volume = {37},
number = {27},
pages = {275109},
doi = {10.1088/1361-6501/ae804a}
}
EUVIMED